EN - English - I
nstruc
tion manual
16
MNVCMBA_1817_EN
10.1 Routine maintenance (to be
performed on a periodic basis)
Consult the use instructions of the
explosion-proof box.
Frequency will depend on the type of
environment in which the product is used.
10.1.1 Inspecting the cables
The cables should not show signs of damage or wear,
which could generate hazardous situations. In this
case extraordinary maintenance is necessary.
10.1.2 Fuses replacement
Maintenance must be performed with the
power supply disconnected and the circuit-
breaker open.
CAUTION! For continued protection against
risk of fire, replace only with same type and
rating of fuse. Fuses must be replaced only
by service personnel.
If necessary, the connector board's fuses can be
replaced (Fig. 3, page 10). The new fuses must comply
with the directions given in the table.
FUSES REPLACEMENT
Supply voltage
Fuse (F1)
Fuse (F2)
24Vac, 50/60Hz
T 8A H 250V 5x20
T 8A H 250V 5x20
120Vac, 50/60Hz
T 4A H 250V 5x20
T 8A H 250V 5x20
230Vac, 50/60Hz
T 4A H 250V 5x20
T 8A H 250V 5x20
Tab.
6
11 Information on disposal
and recycling
The European Directive 2012/19/EU on Waste
Electrical and Electronic Equipment (WEEE) mandates
that these devices should not be disposed of in the
normal flow of municipal solid waste, but they should
be collected separately in order to optimize the
recovery stream and recycling of the materials that
they contain and to reduce the impact on human
health and the environment due to the presence of
potentially hazardous substances.
The symbol of the crossed out bin is marked
on all products to remember this.
The waste may be delivered to appropriate collection
centers, or may be delivered free of charge to the
distributor where you purchased the equipment at
the time of purchase of a new equivalent or without
obligation to a new purchase for equipment with size
smaller than 25cm (9.8in).
For more information on proper disposal of these
devices, you can contact the responsible public
service.
12 Troubleshooting
Contact the VIDEOTEC technical service
or an authorized support centre if the
problems listed below persist or you have
any other issues that are not described
here.
When contacting VIDEOTEC for assistance please
provide the serial number and the identification code
of the model.
PROBLEM
The product does not go on.
CAUSE
Wiring error, blown fuse.
SOLUTION
Make sure the connections are
correct. Check the continuity of
the fuses and replace them with
the indicated models should they
fail.