Page 32
5.9 Privacy
Use this option to set up to 24 privacy zones
Step Action
Result
1
Select dome
MENU from DVR/keyboard
2
Log in
(using engineer pass code)
3
Select
PRIVACY
Default
view
MASK 1
appears
4
Move joystick or arrow keys up/down to select a different
MASK number, 1-24)
5
Move joystick/arrow key right
Cross lines appear on screen
6
Move camera to required view
7
Select
OK
(Vi K/B) or
01
+
preset
(Pelco K/B), or
Preset
,
10
,1
(on DS2) or wait 15 seconds until a red mask patch
appears
Red mask patch appears
8
Scroll to next MASK number (using arrow keys or joystick
UP/DOWN)
Blue mask patch appears
9
Move joystick or arrow key to the RIGHT
Cross lines appear
10
For each new mask position, repeat steps 4 to 7
12
When all mask positions have been created , exit menus
& save by moving joystick left TWICE
‘
Saving config…
’ (appears on
bottom left of screen)
5.10 Alarms
If the alarm option is installed in the power supply, the dome will go to presets when an
alarm occurs. Alarms 1 to 16 map to presets 1 to 16 respectively.
Note that if the alarms are connected directly to the digital recorder (DVR) rather than the
alarm option, the following settings have no effect.
5.10.1 New alarm dwell
When a new alarm occurs, the dome will go to the corresponding preset.
If multiple alarms occur, the presets will be called up in sequence. However, the dome will
wait at each preset position for the dwell time set by this option (in seconds).
5.10.2 Alarm cycle time
If alarms still exist after all alarm presets have been visited for the New alarm dwell time, the
presets of the still active alarms will now be toured using the cycle time (in seconds)
specified in this option.