background image

XT200i QUICK SETUP GUIDE 

Description 

The XT control panel

 is a Videofied wireless, battery operated hybrid alarm system. 

It is designed for residential and small business security applications, as well as both 
indoor  and  outdoor  commercial  applications  (construction  sites,  cell  tower,  remote 
sites, substations...). 

XT  can  be  used  as  a  standalone  alarm  system  or  can  be  integrated  into  an  existing 
alarms system as an upgrade to Videofied features and technology. 

XT has programmable inputs and outputs (outputs available Q1 2011). Programmable 
inputs  and  certain  event  types  can  be  configured  to  capture  video  from  a 
MotionViewer device using the mapping feature. 

The control panel has two easy to access external connectors for upgrading GPRS and 
RF antenna connections. 

Summary of Contents for XT200i

Page 1: ...er remote sites substations XT can be used as a standalone alarm system or can be integrated into an existing alarms system as an upgrade to Videofied features and technology XT has programmable inputs and outputs outputs available Q1 2011 Programmable inputs and certain event types can be configured to capture video from a MotionViewer device using the mapping feature The control panel has two ea...

Page 2: ...ndalone alarm system with 25 wireless Videofied devices 3 programmable inputs and 2 programmable outputs XTender Mode In XTender mode the XT Panel will extend the existing alarm system to include Videofied as video verification and can also work as GPRS cell back up ...

Page 3: ...XT PANEL INSTALLATION 1 Unscrew the 2 screws at the side of the panel to open the control panel 2 Insert the sim card into the provided slot Note Do not insert or remove the sim card when the panel is ...

Page 4: ...order to program the panel 4 Powering the XT Panel Option 1 Option 2 4 x LSH20 Lithium D Cell Used for Standalone or Xtender mode without Programmable Inputs 4 x E95 Alkaline D Cell 12DC power supply Used for Standalone or Xtender mode where Programmable Inputs Mapping will be used 2 1 3 ...

Page 5: ......

Page 6: ... the keys The LED on the keypad will blink rapidly 3 The keypad will display KEYPAD 1 RECORDED if pairing is successful If pairing is not successful repeat step 2 Press the YES key 4 Press the left or right arrow on the keypad to choose your language Press the YES key to confirm your selection 5 The keypad will display RADIO RANGE TEST Run this test to ensure proper pairing with the control panel ...

Page 7: ...pad will display ADJUSTING TIME AND DATE Wait for the screen to change to ask for DATE Year Use the left and right arrow key on the keypad to change the value Press the YES key to confirm Repeat the same steps for others 8 The keypad will display the current date and time and ENTRY COMPLETE Press the YES key to continue 9 The keypad will display CONNECTED TO MONITOR STATION You must press the YES ...

Page 8: ...ress the YES key Use the left and right arrow keys to select the frequency of periodic test and press the YES key to continue Use the left and right arrow keys to select the hour the periodic test will happen Press the YES key to confirm Repeat the same step for minute ...

Page 9: ...se the keypad to name the area 1 Leave blank for default Area 1 and press the YES key to confirm Repeat the same step for the remaining areas 13 Choose the arming option depending on the configurations FROM THE HOST The XT Panel will be on XTender mode that arm disarm off the latching 9 12V on the arming input STANDALONE The XT Panel will be a single system Arm disarm will be controlled by Videofi...

Page 10: ...14 Use the left and right arrow keys to set the Exit Delay time and press the YES key to continue Repeat the same step for Entry Delay Proceed to step 16 ...

Page 11: ... disarming of host This will arm each device one at a time to conserve battery Fast Instant arm all devices Sacrifices battery life Enter a value for Entry Delay and press the YES key Max 255 seconds No Exit Delay when using XTender Mode Enter the amount of time any event will be delayed before transmission and press the YES key Max 600 seconds For ARMING CONFIRMATION select the amount of time of ...

Page 12: ...t 1 By default Port 1 is 888 For IP address enter in 3 digits format Ie 4 9 1 2 2 2 1 1 m u s t b e e n t e r e d a s 049 001 222 011 When done press the ESC NO key to go back to previous menu Press the ESC NO key again 17 The keypad will display GPRS LEVEL Press the YES key to begin the test During test to keep the keypad awake press the left or right arrow keys If the test is successful it will ...

Page 13: ...rea Allocation Press the YES key You may name the camera Leave blank for default CAMERA 1 Press the ESC NO key for the Functional test The keypad will display ENTERING A NEW DEVICE Press the YES key to add more devices Press the ESC NO key to end 19 The keypad will display OPERATION COMPLETED Press the YES key to confirm Make sure the panel is closed and all the devices tampers are depressed befor...

Page 14: ...4 Key in the user code and press the YES key 5 Key in the same user code again and press the YES key to confirm 6 Name the code or leave blank for default ACCESS 2 GPRS ERROR CODES CODES Errors 043 Typographical error in the APN Code username password or a provisioning problem 003 Sim card not detected not inserted 132 SIM card not activated 030 GPRS Level Test No GPRS Signal Event Log No error Fo...