background image

Product Summary

The Indoor Keypad Model XMA is designed for use in 
configuring/programming and operating a Videofied

TM 

 security 

system.  The keypad includes the following features:

>  

Lithium batteries for long life.

>

  2-line, 16-character alphanumeric LCD display

>

  Built-in piezo for status and alarm sounds

>

  Dual tamper function provides detection of both  

  wall and cover tamper.

>

  Transmits check-in/status signal every 8 minutes.

Installation Guidelines

For easier installation, programming and RF testing  
should be completed before mounting the control panel and 
devices. 

Install the keypad and other system devices in the following 
order:

>

  Programming/RF Testing - Program keypad and all other     

  devices into the control panel and test RF communication     
  from each intended device location to the control panel.

>

  Mounting - Mount keypad and devices at the tested location.

Programming/RF Testing*

1

  Open the casing by turning the button toward the opened  

 

padlock symbol and press down lightly on the button to    

 

separate the cover.

2

  Insert 3 (minimum) or 4 (for longer life) SAFT 3.6v Lithium  

 

AA LS14500 batteries.

3A

 

New Installation: 

Put the control panel into 

 

keypad registration mode by pressing the  

 

 

 

programming button of the control panel one time.

 OR

3B

   

Adding to existing system:

  Using a programmed  

 

 

alphanumeric keypad, proceed through menus until the    

 

display shows ADD A NEW DEVICE.  Press 

Yes.

  The  

 

 

display shows PRESS PROGRAM BUTTON OF DEVICE.

 OR

3C

   

Adding to existing system without a keypad:  

 Refer to   

 

the installation manual of the control panel.   

4

  Press and release the programming buttons (CLR and    

 

ESC/NO) on the XMA keypad. The keypad LED will flash.    

 

Wait for keypad display to show KEYPAD# RECORDED.

 Press 

Yes.

 The display shows LANGUAGE: ENGLISH. Press  

 

Yes

.  (This prompt will only appear when performing a    

 

new installation).

6

  Display shows RADIO RANGE TEST? Press YES, the  

 

 

keypad starts displaying the number of successful pings    

 

to and from the control panel out of 9 (0/9 to 9/9).   

 

 

Devices must be installed in a location with a stable 9/9 RF  

 

test result to ensure reliable communication. 

7

 Press 

YES

 to end radio range test, then press 

Esc/No.

 

 

Note:  If this is a new installation (3A), the keypad display  

 

 

 

prompts other system configuration data.  If adding a keypad to  

 

 

an existing (operational) system, proceed to step 8.

8

  When finished, exit from configuration mode. 

  

Note:  The control panel automatically assigns alphanumeric    

 

 

keypads automatically to Area 1 (Entry/Exit delay)   

*For complete details, refer to the control panel installation manual.

www.videofied.com

I N S T A L L A T I O N   D A T A   S H E E T

Keypad XMA

Made by RSI VIDEO TECHNOLOGIES

1010-XMAIN July 2012

Summary of Contents for XMA

Page 1: ...anel one time OR 3B Adding to existing system Using a programmed alphanumeric keypad proceed through menus until the display shows ADD A NEW DEVICE Press Yes The display shows PRESS PROGRAM BUTTON OF DEVICE OR 3C Adding to existing system without a keypad Refer to the installation manual of the control panel 4 Press and release the programming buttons CLR and ESC NO on the XMA keypad The keypad LE...

Page 2: ...e needed 4 Place base on mounting surface so holes line up with pilot holes anchors and secure base with appropriate screws 5 Attach Keypad to base and secure by turning the button to the closed padlock symbol Note The XMA Keypad is a supervised device and must be permanently mounted This product is not intended for portable use Mounting Holes 2 LCD Overview Icons for entry mode a z Lowercase A Z ...

Page 3: ...ey are looking for By pressing and holding the 1 key the line with all symbols will show Use the arrow keys to select the symbol and press OK to confirm Capital Letter Press and hold appropriate letter key then repeat press Auto Repeat mode When a user holds an arrow key the keypad will scroll all available values Re sync and Enrollment Press and release ESC NO and CLR buttons simultaneously 3 Pro...

Page 4: ...he user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Radio frequency radiation exp...

Page 5: ...AES algorithm encryption Supervision Panel polls devices every 8 minutes Antenna Integrated Tamper detection Wall and cover tampered Keypad Keys 23x Keys Allowed Time for Code Entry 60s Number of Illegal codes 186 depending on panel features User code input attempts before lockout 5 Lockout duration 90 seconds Memory Lifetime No Limit Flash Memory Physical Data Material ABS UL94 V0 Dimensions LxWx...