Product Summary

The Door Contact Models CT 600 (white) CT 610 (brown), 
are wireless, universal door contacts designed for use in 
RSIalarm™ security systems. The contact includes the 
following features: 

 Lithium battery for long life

 External input for normally closed (NC) intrusion devices

 Dual tamper function provides detection for both wall 

  and cover tamper.

 Transmits check-in/status signal every 8 minutes

Installation Guidelines

For easier installation, programming and RF testing 
should be done to check for good communication between 
the control panel and all system devices before mounting 
system devices. Install the detector and other system 
devices in the following order:

>

  Programming/RF Testing—program detector and 

  all other devices into the control panel and test  RF 
  communication from each intended device location 
  to the control panel.

>

  Mounting—mount detector at the tested location.

Programming/RF Testing

The following provides summarized steps for device 
programming and testing. For complete details, refer 
to the control panel installation manual.

1

  Loosen bottom screw, separate base

 

from detector and install battery.

2

  Re-attach base to secure tamper switch.

3

  Put control panel into programming/ 

 

 

 

 confi guration mode.

4

  Using a programmed alphanumeric

 

keypad, proceed through menus 

 

until the display shows ADD A

 NEW 

DEVICE.

5

 Press 

Yes.

 The display shows 

 

PRESS PROGRAM BUTTON OF DEVICE.

6

  Press and release program button on detector using a  

 

 

paper clip end. The detector LED fl ashes. Wait for keypad  

 

display to show DETECTOR (1 - 25) RECORDED.

7

 Press 

Yes.

 The display shows RADIO RANGE TEST? 

 Press 

Yes

 again. The detector LED starts fl ashing and  

 

 

keypad display shows TEST IN PROGRESS.

8

  Take detector to its intended mounting location and 

 

make sure LED fl ashes continuously, indicating good  

 

 

communication with control panel.

9

 Press 

Yes

 to end radio range test, then press 

Esc/No.

10

  The display shows AREA 

 

ASSIGNMENT AREA: 1. Press

 

either arrow button repeatedly 

 

until desired AREA  number 

 

appears, then press 

Yes.

11

  The display shows PROTECT AN 

 EXTERNAL 

ACCESS? 

Press 

Yes

 or  

 

 

Esc/No,

 whichever is appropriate  

 

 for 

this 

device.

12

  The display shows NAME + LOCATION. 

 

Enter appropriate device name/location (up to 

 

16 characters), then press 

Yes.

 The display shows 

 

the device number and name for your verifi cation.

13

 Press 

Yes.

 The display shows FUNCTIONAL DEVICE  

 

 TEST? 

Press 

Yes 

again and verify detector operation. 

 

For example, move magnet next to detector to make 

 

LED go out, then move magnet away from detector 

 

to make LED turn on indicating detection. 

14

 Press 

Yes

 to end detection verifi cation.

15

  The display shows ENTERING A NEW DEVICE? 

 

Repeat steps 1 - 14 for remaining detectors.

16

 When fi nished, exit from confi guration mode.

Screw

Program Button

LED

I N S T A L L A T I O N   I N S T R U C T I O N S

Door Contact Models CT600/610

Manufactured by RSIalarm

Document No. 1008-c November 2006

Reviews: