background image

6. Technical specifications

6.1. Phoenix Inverter Smart

Phoenix Inverter Smart

12/1600

24/1600

48/1600

12/2000

24/2000

48/2000

12/3000

24/3000

48/3000

24/5000

48/5000

Parallel and 3-phase operation

No

INVERTER

Input voltage range

9.3 - 17V, 8.6 - 34V or 37.2 - 68V

AC Output

230Vac ±2%, 50Hz or 60Hz ± 0,1% (Non-linear load, crest factor 3:1)

Continuous output power at 25ºC 

(1)

1600VA

2000VA

3000VA

5000VA

Continuous output power at 25ºC

1300W

1600W

2400W

4000W

Continious output power at 40ºC

1200W

1450W

2200W

3700W

Continious output power at 65ºC

800W

1000W

1700W

2800W

Peak power

3000VA

4000VA

6000VA

10000W

Short-circuit output current

13.9A

17.4A

26.0A

43.5A

Dynamic DC low shut down

Load dependant, configurable, see 

Dynamic cut off [8]

 chapter

Maximium efficiency (12/ 24 /48V)

92 / 94 / 94%

92 / 94 / 94%

93 / 94 / 95%

95 / 96%

Zero load power 12 / 24 / 48 V

8 / 9 /11W

8 / 9 / 11W

12 / 13 / 15W

18 / 20W

Zero load power in ECO mode

0.6 / 1.3 / 2.1W

0.6 / 1.3 / 2.1W

1.5 / 1.9 / 2.8W

2.2 / 3.2W

GENERAL

Programmable relay

DC rating 4A@35V or 1A@60V, AC rating: 3A@230V

Stop & start power ECO-mode

Adjustable via VictronConnect app

Protection

Output short circuit, overload, low battery voltage, high battery voltage, over

temperature, AC voltage on AC output, high DC ripple.

Bluetooth wireless communication

For remote monitoring and system integration

VE.Direct communication port

For remote monitoring and system integration

Remote on/off connector

Yes

Operating temperature range

-40 to +65ºC (fan assisted cooling)

Humidity (non-condensing)

max 95%.

Maximum altitude

2000m

Pollution degree classification

PDII

Over voltage category

Mains: OVII

ENCLOSURE

Material and colour

Steel (blue RAL 5012; and black RAL 9017)

Protection category:

IP21

Battery connection terminals

M8 bolts

M8 bolts

12 V/24 V: 2+2

M8 bolts 48 V:

M8 bolts

24 V: 2+2 M8

bolts 48 V: M8

bolts

AC output connection terminals

Screw terminals

Weight

12kg

13kg

19kg

29kg / 28kg

Phoenix Inverter Smart Manual

Page 16

Technical specifications

Summary of Contents for Phoenix Inverter Smart

Page 1: ...Phoenix Inverter Smart Manual Rev 00 05 2022 ENGLISH...

Page 2: ...ect settings 7 4 3 1 Dynamic cut off 8 4 4 Programmable relay 9 4 5 Firmware update 9 4 6 Reset settings to default 10 5 Operation 11 5 1 Inverter 11 5 1 1 On Off Push button 11 5 1 2 On off Switch 5k...

Page 3: ...t is likely that the grounding protection has been damaged the product must be turned off and secured against unintended operation please contact qualified service staff Ensure that the equipment is u...

Page 4: ...d ECO mode sensitivity level Programmable relay To transfer the load to another AC source The automatic transfer switch For inverters we recommend our Filax2 automatic transfer switch The Filax2 featu...

Page 5: ...additional VE Direct cable is needed for this 2 6 Remote on off control The inverter can be remotely turned on or off in the following ways Via the VictronConnect app With an optional external switch...

Page 6: ...0 C humidity 95 non condensing Note that in extreme situations the inverter s case temperature can exceed 70 C Excessive high ambient temperature will result in a reduced service life reduced peak pow...

Page 7: ...bsite Battery connection procedure Use an insulated box spanner in order to avoid shorting the battery The maximum torque is 11Nm Avoid shorting the battery cables Proceed as follows to connect the ba...

Page 8: ...annot be accidentally turned back on by another user Inverter control panel If a Phoenix Inverter Control VE Direct panel is used it needs to be connected to the inverter remote connector as is indica...

Page 9: ...load adjustable the inverter will go back to normal operation mode Once the load drops below a certain level the inverter will go back to ECO mode Below table indicates the default settings and settin...

Page 10: ...elow graph shows the discharge ratio versus battery voltage curve for the different battery types You can see that the lithium curve LiFePO4 is nearly flat compared to the OPzV and OPzS curve The curv...

Page 11: ...that it is time to do something charge the battery reduce the load and so forth in order to prevent a power outage Low battery Relay on during normal operation The relay will switch off once there is...

Page 12: ...following way Navigate to the inverter settings by clicking on the cog symbol in the right top corner Click on the 3 dot symbol in the right top corner Select Reset to defaults from the menu and the s...

Page 13: ...cut off the supply current completely The switch is located at the bottom right of the inverter next to the battery cable entries 5 1 3 ECO Mode The inverter can be switched to ECO mode via the Victr...

Page 14: ...than the inverter rating and that if this situation continues the inverter will switch off due to an overload alarm Reduce the AC load The green inverter LED is blinking with a fast double pulse The r...

Page 15: ...attery voltage alarm The inverter has shut down due to high battery voltage Reduce the DC input voltage check if the battery voltage is correct and if the battery bank is wired correctly Also check if...

Page 16: ...ee the Dynamic cut off 8 chapter High battery voltage The inverter will shut down when the DC input voltage is too high The LEDs will signal shutdown due to high battery The inverter will first wait 3...

Page 17: ...ring via a GX device GlobalLink and the VRM portal The inverter can be connected to a GX device like a Cerbo GX or a Color Control GX When connected the GX device will display the inverter on the syst...

Page 18: ...load power in ECO mode 0 6 1 3 2 1W 0 6 1 3 2 1W 1 5 1 9 2 8W 2 2 3 2W GENERAL Programmable relay DC rating 4A 35V or 1A 60V AC rating 3A 230V Stop start power ECO mode Adjustable via VictronConnect a...

Page 19: ...9 x 125mm 485 x 219 x 125mm 533 x 285 x 150mm 12V 485 x 285 x 150mm 24 28V 595 x 295 x 160mm 24V 555 x 295 x 160mm 48V STANDARDS Safety EN IEC 60335 1 Emission Immunity EN 55014 1 EN 55014 2 EN IEC 61...

Page 20: ...7 Appendix 7 1 Connection overview Connections 1600VA model Connections 2000VA model Phoenix Inverter Smart Manual Page 18 Appendix...

Page 21: ...Connections 3000VA model Phoenix Inverter Smart Manual Page 19 Appendix...

Page 22: ...ation information floating ground 1600VA and 2000VA models Ground wire G connects the output neutral to ground It must be re positioned to a dummy terminal if a floating output is required When a floa...

Page 23: ...eutral to ground It must be re positioned to a dummy terminal if a floating output is required When a floating output is obtained the current reading at no load can show an offset of around 100 150mA...

Page 24: ...0000 Phoenix Inverter 24 1600 230V Smart PIN482160000 Phoenix Inverter 48 1600 230V Smart PIN122200000 Phoenix Inverter 12 2000 230V Smart PIN242200000 Phoenix Inverter 24 2000 230V Smart PIN482200000...

Page 25: ...0 175 6 5 4 x 46 4 55 87 5 87 5 98 6 2 3 x 32 5 Rev00 Dimensions in mm Dimension Drawing Phoenix Inverter 3000VA Smart PIN122300000 Phoenix Inverter 12 3000 230V Smart D E F C 1 2 3 4 B A 3 2 1 5 C D...

Page 26: ...87 5 87 5 98 6 2 3 x Rev00 Dimension Drawing Phoenix Inverter 3000VA Smart PIN242300000 Phoenix Inverter 24 3000 230V Smart PIN482300000 Phoenix Inverter 48 3000 230V Smart Dimensions in mm D E F C 1...

Page 27: ...9 6 5 4 x 32 5 55 87 5 87 5 98 6 2 3 x Rev00 Dimension Drawing Phoenix Inverter 5000VA Smart PIN242500000 Phoenix Inverter 24 5000 230V Smart PIN482500000 Phoenix Inverter 48 5000 230V Smart Dimension...

Reviews: