10. Technical specifications
10.1. Specifications 100/30 and 100/50
MPPT 100/30
MPPT 100/50
Battery voltage (auto select)
12V or 24V
Rated charge current
30A
50A
Nominal PV power, 12V
1a,b
440W
700W
Nominal PV power, 24V
1a,b
880W
1400W
Maximum PV open circuit voltage
100V
100V
Max. PV short circuit current
2
30A
50A
Maximum efficiency
98%
Self-consumption
12V: 30mA / 24V: 20mA
Charge algorithm
Multi-stage adaptive (eight pre-programmed algorithms) or user defined
algorithm
Charge voltage 'absorption'
14.4V / 28.8V (adjustable)
Charge voltage 'float'
13.8V / 27.6V (adjustable)
Charge voltage 'equalization'
3
16.2V / 28.8V (adjustable)
Temperature compensation
12V: -16mV/°C / 24V: -32mV/°C
Protection
Output short circuit, over temperature
Operating temperature
-30°C to +60°C (full rated output up to 40°C)
Humidity
95%, non-condensing
Maximum altitude
5000m (full rated output up to 2000m)
Environmental condition
Indoor type 1, unconditioned
Pollution degree
PD3
Data communication
VE.Direct port
4
ENCLOSURE
Colour
Blue (RAL 5012)
Power terminals
16 mm² / AWG6
Protection category
IP43 (electronic components), IP22 (connection area)
Weight
1.3 kg
Dimensions h x w x d
130 x 186 x 70 mm
STANDARDS
Safety
EN/IEC 62109-1, UL 1741, CSA C22.2
1a) The solar charger will limit input power if more PV power is connected.
1b) The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher short circuit current may damage the solar charger in case of reverse polarity connection of the PV array.
3) Equalization is by default disabled.
4) For more information on data communication see the
our website.
MPPT solar charger manual
Page 52
Technical specifications