10 

 

 

10.2.1.Main user control panel. 

To visualize every function from the display  it is necessary to touch the respective icon. The blue arrow in the sub menu is for 
returning to the previous screen. By  pressing 

SAVE 

all corrections are saved. The left  and right  arrows are for decreasing and 

increasing the value of the respective parameter. 

 

Display symbol 

Description 

00/00/00 

Date display 

day/month/year 

00 : 00 

Hour display 

Hour : Minutes 

 

 
 

Indoor temperature 

 
 
 

The number in the rectangle shows the current room 
temperature. 
The number in the circle indicates the desired room 
temperature. 
We need to touch the icon with the number for room 
temperature. An additional page opens, where we can set the 
desired temperature (min.2oC-max.45oC). 

The desired temperature is entered using the left and right arrows. The value is saved using the 
Save button. When you touch the button, a green bar appears at the bottom of the display. Wait 
until it is full to execute the command. Hiding the green bar means that the value is stored 
correctly. The return icon is removed during the memorization process. It appears after the 
process is completed. 
If there is no connection to the controller for more than 6 seconds, the value is not saved! 

Manual feed 

Pressing  the  icon  would  start  the  screw  conveyor  for  10  seconds!  When  this  time  is  over,  the 
screw conveyor stops again and waits until a new icon click is done.  
 
The icon would only be visible in Ready Mode, whereas, respectively, on starting of the fireplace 
it will disappear!  

Main menu and 
service settings 

When the icon is touched, a new page with the main menu is opened.  

 

Activated timer 

Red  colour: the timer is activated and waiting 
for the set time to stop the stove. 

                                                                                                             

Activated timer 

The green one shows that the timer has been 
set  active  and  is  waiting  for  the  fireplace  to 
start                                                                                                                                                  

 

 
 

 

 

 

 

 
 
 
 
 

10.2.2.Types of modes of the control unit. 

 

 

READY MODE 

 

 

 

BURNING 

 

 

 

START MODE 

 

 

 

MODULATION

 

 

 

FUEL MODE 

 

 

 

CLEANING

 

 

 

IGNITION MODE 

 

 

 

ECO MODE

 

 

Summary of Contents for VITTORIA 8

Page 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8...

Page 2: ...ONTROL UNIT 10 10 2 3 MAIN MENU 11 10 2 4 INSTALLER SETTINGS 13 10 2 5 SERVICE TECHNICIAN SETTINGS 13 10 3 OUTS TEST 14 11 INSTRUCTION MANUAL 14 11 1 WOOD PELLETS LOADING 14 11 2 WOOD PELLET REFUELLIN...

Page 3: ...ailure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the fo...

Page 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...

Page 5: ...Alarm Exhaust gases Pressostat Connected to the combustion chamber It reads the values of the vacuum in the combustion chamber and compares it with the pressure in the room Temperature sensor of the...

Page 6: ...m Pressure Switch Pressostat Measures the vacuum in the combustion chamber 7 Operating mode Pellet stove works with wood pellets They are cylindrical granules made of pressed wood whose combustion is...

Page 7: ...rea Pellet stove is designed developed programmed and tested to operate with wood pellets class A1 according to EN plus and BDS EN ISO 17225 2 2014 with the following parameters Maximum diameter 6 mm...

Page 8: ...to ensure a sufficient supply of oxygen necessary for combustion Additionally it can be delivered outside air through a pipeline of 50 mm In this case it is possible to emerge condensate If necessary...

Page 9: ...llet stove is coated by high temperature resistant paint but not against corrosion In case of accumulation of dust surfaces can be cleaned with a soft brush or a dry cloth but in any case not with a d...

Page 10: ...utton a green bar appears at the bottom of the display Wait until it is full to execute the command Hiding the green bar means that the value is stored correctly The return icon is removed during the...

Page 11: ...le is connected 0 no module 1 a module is present but is not connected 2 a module is connected to the router Languages Here there is a Control Unit Language shortcut key The system offers four languag...

Page 12: ...e fireplace will stop The settings have been restricted in four access levels The first level is Installer The second level is Service Technician The third level is Delete Errors with a password 7777...

Page 13: ...ion can do among four display languages Bulgarian English Dutch and German 10 2 5 Service technician settings Types of settings for service technician entered with service technician password Paramete...

Page 14: ...pellets loading The capacity of the pellet fuel hopper is 24 kg The opening for charging the hopper is with dimensions 167 300 mm If the hopper is left without pellets the pellet stove will stop worki...

Page 15: ...in the end P1 Switching among these is based on the temperature pre set as room temperature If the room temperature is set to 30 in the Modulation 5 Menu the Thermal Difference one should set is 4 in...

Page 16: ...ve was not used for an extended period Clean the ignition 12 3 Seasonal maintenance performed by the installer The user has to contact the installer to perform the seasonal maintenance Disconnect the...

Page 17: ...cted alarm s activation on the right To delete the alarms on the right enter the password 7777 To delete the alarms on the left too enter the password again Pressure Switch Activated if insufficient v...

Page 18: ...an the flue gasses be sent out directly through the wall NO Removal must be in accordance with existing standards For proper operation of the pellet stove the chimney metal or masonry has to be comple...

Page 19: ...r 4 Ignition 18 Left side plate 5 Pressure switch 19 Right side plate 6 Controller set 20 Special tool 7 Display 21 Fume temperature sensor 8 Crossflow blower 22 Thermostat of the pellet fuel hopper 7...

Page 20: ...Victoria 05 Ltd 20...

Page 21: ...03 2021 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 21...

Page 22: ...Victoria 05 Ltd 22...

Page 23: ...maining population For other countries please contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following...

Page 24: ...for repairs under warranty Company Receipt date Type of repair Delivery date Carried out Victoria 05 Ltd 1B Ivan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 e mail in...

Reviews: