background image

 

UG:001 

Page 3

Set Up

The evaluation board should be set up as follows.

Note:

 Care should be taken to avoid reversing polarities if connecting to the opposite (solder) side of the board.

+IN, –IN

Connect a high-quality, low-noise power supply to the +IN and –IN terminals of the evaluation board. 

The interconnect leads should be heavy gauge and as short as possible. Additional capacitance may 

have to be added on the evaluation board to make up for impedances in the interconnect leads as 

well as deficiencies in the source. It is important to remember that noise from the source, as well as 

any input source voltage drops, will appear at the output of the BCM

®

 multiplied by its K factor. Test 

points 4 (–IN) and 5 (+IN) can be used to monitor the input and are located on the PCB adjacent to the 

input terminals.

+ OUT, –OUT

An electronic or passive load should be connected to +OUT and –OUT terminals of the evaluation 

board with short heavy-gauge leads. Most commercially available electronic loads do not have current 

slew rates capable of fully exercising the BCM. The evaluation board can be connected directly to 

the application for which the BCM is intended. However, the interconnect impedances between 

the evaluation board and the application can greatly affect the transient response. For applications 

where transient response is critical, the user should consider mounting the BCM directly to the target 

application PCB. Test points 6 (–OUT) and 7 (+OUT) can be used to monitor the output and are located 

on the PCB adjacent to the output terminals.

Output Voltage Measurement Jack (J1)

This connector is provided to make accurate measurements of the output voltage of the BCM. Many 

types of scope probes may be directly connected to this point if the probe is equipped with a removable 

plastic sheath. To avoid creating ground loops when making measurements of the output or input 

voltage, these measurements should be made separately.

Paralleling

The paralleling and current sharing capability of the devices can be demonstrated by stacking multiple 

evaluation boards and interconnecting the inputs and outputs with standoffs of sufficient current 

handling capability to create a 3-dimensional array. See Figure 3. When paralleling BCMs, the PC ports 

should be connected together to ensure the outputs turn on simultaneously. 

Summary of Contents for VI Chip BCM

Page 1: ... operating limits The data sheets are available for downloading at www vicorpower com It is important to remember the fast response of most BCMs can readily show the limitations of the source load and associated wiring connected to the evaluation board Care should be exercised to minimize stray source and load impedances in order to fully exercise the BCM Please refer to Figure 1 for locations of ...

Page 2: ... 9 OUT OUT C1 BCM J1 TP1 TP2 TP7 TP4 TP6 TP5 OUT OUT C1 2 2 µF 450 V IN IN TM RSV PC J1 TP5 TP7 TP6 TP2 TP1 TP4 In PC RSV TM In Out Out Out Out BCM Figure 1 BCM evaluation board demo layout and dimensional drawing component side Figure 2 BCM evaluation board schematic ...

Page 3: ... evaluation board can be connected directly to the application for which the BCM is intended However the interconnect impedances between the evaluation board and the application can greatly affect the transient response For applications where transient response is critical the user should consider mounting the BCM directly to the target application PCB Test points 6 OUT and 7 OUT can be used to mo...

Page 4: ... bias supply a Connecting PC to the IN will disable the BCM b Connecting a DVM or oscilloscope between PC positive and IN negative will indicate the status of the BCM Please note that the BCM does not have active current sinking capability c Connecting a load between PC positive and IN negative will provide a primary referenced bias supply Efficiency Measurement As the BCM can deliver and consume ...

Page 5: ...rator Be careful not to touch any exposed surface Certain BCMs may operate at potentially dangerous voltages use care in such cases The evaluation board is not intended for use in end item equipment Ordering Information The BCM evaluation boards can be ordered from the Vicor website www vicorpower com To order the demo boards substitute BCM with BCD in BCM part number See http www vicorpower com d...

Page 6: ...ne whether the Vicor product is suitable and fit for your applications and products and to implement adequate design testing and operating safeguards for your planned application s and use s VICOR PRODUCTS ARE NOT DESIGNED AUTHORIZED OR WARRANTED FOR USE IN LIFE SUPPORT LIFE CRITICAL OR SAFETY CRITICAL SYSTEMS OR EQUIPMENT VICOR PRODUCTS ARE NOT CERTIFIED TO MEET ISO 13485 FOR USE IN MEDICAL EQUIP...

Page 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Vicor BCD384F120T300A00 ...

Reviews: