INSTRUCTIONS FOR

L

INSTALLATION AND OPERATION

MODEL VI 300X-IA ALARM INTERFACE

1. INTRODUCTION

The information in this manual covers the installation,

program, and displaying a special alarm message on the

operation and maintenance of the 

 Alarm Inter-

alarm monitors. The green ALARM LED on the front

face. This unit should only be installed by a qualified

panel of the 

 illuminates when there is an

technician using approved materials and wiring practices in

active alarm in the unit, and the unit generates a warning

conformance with national, state, and local electrical codes.

tone. The tone may be disabled.

The 

 Alarm Interface 

 

 alarm

devices to be connected to Vicon Nova

( V P S ) systems.

In the basic configuration, up to 32 alarms may be con-
nected to a single 

 while an expanded unit

 accepts up to 64. Multiple 

may be cascaded together for further expansion. In this
manual, the model number 

 is used to desig-

nate all models, unless specified otherwise. Refer to Table

1 for all model variations.

Acknowledging individual alarm inputs is performed
from the operator control panel. Enabling and disabling
individual alarm inputs can be done by software in the
system CPU. The 

 is compatible with all

Nova VPS digital control 

 It connects to them with

a parallel data interface.

Both models are compatible with the earlier 

alarm interface and with the current 

 alarm

interface with relay follow. The 

 provides

an individual relay closure output for each alarm input.

A single auxiliary relay output activates when any alarm
input goes active. This relay may be used to control some
external device, such as a VCR. In the case of multiple
cascaded 

 only the auxiliary output on the X-IA

that received the alarm goes active. The aux outputs on
the other 

 do not go active.

Up to four 

 units may be cascaded in a

daisy-chain to provide a maximum of 256 alarm inputs on

a single CPU trunk line. Alternatively, up to eight of the

basic 

 may be cascaded to provide 256 inputs.

When used 

 the 

 system, up to four groups

of daisy-chained 

 may be connected to the

CPU, depending on the CPU configuration.

The alarm inputs may be configured as normally closed
or normally open using on-screen programming in the
Nova CPU. Alarm inputs are 

 compatible.

The 

 complies with FCC rules for a Class A

digital device.

TABLE 1

MODELS AND PRODUCT CODES

When the 

 senses a change in the status of one

of its alarm inputs, it transmits the information to the Nova
CPU, which announces the alarm to the operator and which
may also execute a preprogrammed response to the alarm.
Such responses include displaying the video from the
camera associated with the alarm on selected alarm moni-
tors, causing a camera station to carry out a preset-position

M o d e l

Number

Product

Code

Description

WARNING: TO PREVENT RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

Product specifications subject to change without notice.

Vicon part number 8006-8849-01-00

Copyright 

 1997 Vicon Industries Inc. All rights reserved.

Vicon and its logo 

 registered trademarks of Vicon Industries Inc.

VICON INDUSTRIES INC. 

89 ARKAY DRIVE, HAUPPAUGE, N.Y. 

 

TEL: 

 

 

FAX: 

 

TOLL FREE: 

i-800-645-91 

16 

UK: 

 

 

INFOFAX: 

l-800-287-1207 

WORLD WIDE WEB: 

Summary of Contents for V1300X-IA

Page 1: ...liary relay output activates when any alarm input goes active This relay may be used to control some external device such as a VCR In the case of multiple cascaded X IAs only the auxiliary output on t...

Page 2: ...type plug 12 Power Cord Protection Power suoolv cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them payin convenience receptacles an B p...

Page 3: ...e damaged 2 INSTALLATION 2 1 Unpacking and Inspection All Vicon Equipment is inspected and tested before 2 1 2 INSPECTION FOR CONCEALED leaving the factory It is the carrier s responsibility to DAMAGE...

Page 4: ...asic 32 input model has one large printed circuit board PC board while the ex panded 64 input model has two large PC boards The lower board is designated the master and the upper board is the slave or...

Page 5: ...imple and clear as possible only the ON status is marked A dash means OFF or OPEN TABLE 3 SETTING ADDRESS SWITCH 1 CAUTION A Do not set any two of the switches the same The unit will not function When...

Page 6: ...1 2 Installing the Unit in a Rack 1 2 3 Find the two rack mounting brackets Table 2 item 2 and the four flat head screws item 1 in the accessory kit Attach one of the brackets at each end of the unit...

Page 7: ...t 120 VAC The labelling on the rear panel for the relay output has the following meaning NC Normally closed C Common or ground NO Normally open Connect the two wires from the auxiliary equipment such...

Page 8: ...connector labeled IN on the next unit in line and repeat for all units No more than eight V1300X IAs or four V1300X IA EXs can be con nected together on a single trunk line Some CPUs have more than o...

Page 9: ...tch turns the audio alarm tone on or off 4 MAINTENANCE The V1300X IA requires no scheduled maintenance If it is necessary to change the fuse locate the IEC320 connector on the rear panel Figure 3 Remo...

Page 10: ...edure when returning a unit to the factory 2 Attach a sheet of paper to the unit with the fol lowing information 1 Call or write Vicon for a Return Authorization R A at one of the locations listed bel...

Page 11: ...TABLE 7 CONNECTOR NUMBER VS ALARM ADDRESS LOWER CONNECTOR ROW TBI TB4 X849 1297 11...

Page 12: ...TABLE 8 CONNECTOR NUMBER VS ALARM ADDRESS UPPER CONNECTOR ROW TB7 TBlO I Connector Number I Alarm Nos I Alarm Nos Alarm Nos 97 128 181 192 225 256 I 12 X849 1297...

Reviews: