Event Setting
9.1
Alarm Out
This section is designed to set up detailed settings for alarm output(s) when events occur. Make sure
you have enabled alarm output in each event section to activate this function.
Figure: Alarm Output Settings
Alarm Out
Enable:
Select “On” to activate this function.
Method: Pulse/Normal
There are 2 methods to proceed with alarm output. The fields available change according to method.
Normal: The standard method to execute alarm output function, where user can define a duration
from options in Post Duration dropdown menu.
Figure: Normal Method Settings
Pulse: Selecting this method, user can specifically define both the duration and interval time
individually for alarm output. Additionally, counts for alarm output can also be customized.
Figure: Pulse Method Settings
Post Duration: Infinite/5/10/15/30 (sec)
Set a period of duration for alarm output under Normal method. Infinite means unlimited and
continuous triggering for alarm output.
For Pulse Method:
Type: NO/NC
Define which type to use for triggering alarm output.
NO (Normally Opened): An alarm will be triggered when the external contact closes.
NC (Normally Closed): An alarm will be triggered when the external contact opens.