To be done before spreading
69
The following will be achieved with the fertiliser and spreading chart
from the example (see the next page):
The advised discharge point with a working width of 18 metres and a
driving speed of 8 km/h, but with an application rate of 165 kg/ha is: L.
Because the flow rate of 40 kg/min is below 50 kg/min., it is better to
use fine application.
Set the levers for the discharge point for both spreading discs to L,
→
see instructions in paragraph »Discharge point« on page 62.
Install both fine application plates,
→
see instructions on page 66.
Multiply the flowrate of 40 kg/min with a factor of 3. Result: 40 x 3
= 120 kg/min.
Find the line in the spreading chart with the nearest flowrate.
Result: the line with the flowrate of 118 kg/min.
Read the relevant dosing setting. Result: dosing setting 60+0.
Set the value for both spreading discs as per instructions. Do not
change the setting for the discharge point!
→
see instructions in paragraph »Application rate« on page 63.
Do a calibration test to check the dosing setting,
→
see instructions in paragraph »Calibration test« on page 75.