Maintenance
133
Set the position of the
dosing mechanism
The dosing mechanism must be mounted exactly in the middle above
the spreading discs. The agitator axle must turn freely from the seal
ring.
Open the sieves and lock them.
Remove the agitator from the agitator axle.
Check if the distance between the agitator axle and the seal ring is
the same on all sides.
If the distance is not equal all over the position of the dosing plate can
be changed with regards to the agitator axle.
Turn the nuts on the 4 fastening bolts with which the dosing
mechanism is attached to the hopper a few times to loosen them.
Move the dosing plate so that the distance between the agitator
axle and the seal ring is the same on all sides.
Fasten the nuts on the 4 fastening bolts again without moving the
dosing plates again.
Put the agitator back on.
Reattach the dashboard with the three fixing knobs.
Check the connections as described in
→
paragraph »Check the setting mechanism of the discharge
point« on page 137.
agitator
agitator axle
agitator axle
Seal ring
Nut
fastening bolt
Lock nut