Maintenance
113
Net roller sensor
Check, clean and adjust the net feed roller sensor before the season
and every 500 bales.
Distance (R) must be 4 mm at the sensor.
The sensor is located to the left of the net drive roller.
Adjust the net feed roller sensor as follows:
> Loosen the screws on the sensor mounting.
> Set the sensor to distance R=4 mm.
> Tighten the screws on the sensor mounting.
Twine guide sensor
Check, clean and adjust both twine guide sensors every 3,000 bales.
Distance (G) for the twine guide sensors must be 4 mm.
A star wheel sensor is located on the right-hand star wheel on the twi-
ne carriage (right-hand side door open). The twine carriage sensor is
almost centrally positioned behind the twine carriage.
> Loosen the screws on the sensor mounting.
> Set the distance G between the star wheel sensor and twine car-
riage sensor to 4 mm.
> Tighten the screws on the sensor mounting.
Net roller sensor
Net drive roller
Twine guide sensors
Summary of Contents for RF 2235
Page 5: ...Inhaltsverzeichnis 5...