background image

 

 

 
 
 
 
 

 

 

Vicon part number 8009-8123-00-03 

 

 

 

 

Section 4 Rev 503 

 

    

                                                              

XX123-00-03  

 

 
 
 
 
 

AURC-NIU NETWORK INTERFACE UNIT FOR 

AURORACORD DIGITAL RECORDER

  

 
 
 

 

 

   

 

 

 
 
 
 
 
 
 
 
 

Copyright © 2003 Vicon Industries Inc. All rights reserved. 
Product specifications subject to change without notice. 
Vicon and its logo are registered trademarks of Vicon Industries Inc. 
Windows is a trademark of Microsoft Corp. 

 
 
 
 
 
 
 

VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 

TEL: 631-952-CCTV (2288)  FAX: 631-951-CCTV (2288)  TOLL FREE: 800-645-9116 

24-Hour Technical Support: 800-34-VICON (800-348-4266) 

UK: +44 (0) 1489 566300    WEB: www.vicon-cctv.com

 

Summary of Contents for Aurc-Niu

Page 1: ...oduct specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc Windows is a trademark of Microsoft Corp VICON INDUSTRIES INC 89 ARKAY DRIVE...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...XX123 00 03 Rev 503 Network Interface Quick Installation i Quick Installation Connections to Install the IPInstaller...

Page 6: ...ii Quick Installation XX123 00 03 Rev 503 Network Interface Connections for Operation Standalone...

Page 7: ...XX123 00 03 Rev 503 Network Interface Quick Installation iii Network...

Page 8: ......

Page 9: ...ynamic IP address installed into the Interface will not provide access over a WAN In any case the specific video of any particular AurorAcorD will be displayed on the PC that is controlling it The pro...

Page 10: ...nterface for IP installation and also connects interface to AurorAcorD for operation ETHERNET RJ45 10Base T 100Base T network connector used for Wide Area Network WAN or Local Area Network LAN PRESET...

Page 11: ...Copy and paste the file named IPInstaller exe and place it on your desktop See Figure below 4 Double click on the file named Vicon DVR the Vicon DVR application will self install onto the PC See Figu...

Page 12: ...etting Assign and enter a unique IP Address with appropriate Subnet Mask and Gateway numbers For a Standalone installation a valid IP address is 10 0 0 1 254 The first NIU can have address 10 0 0 1 th...

Page 13: ...ess is being assigned to multiple NIUs concurrently the IP address associated with the MAC address of the previous NIU must be cleared from the ARP table before the next NIU can be assigned the IP add...

Page 14: ...5244 01 to the SERIAL port of the AURC NIU and one of the AurorAcorD COM ports Use only the supplied cable Note Refer to the AurorAcorD manual XX091 for information on settings for the COM port for s...

Page 15: ...he PC monitor settings must be 1024 x 768 pixels minimum and color setting equivalent to 32 bit for screen image to display correctly Network Considerations The AurorAcorD Digital Recorder can be used...

Page 16: ...size of the video image displayed When set at 1024 the Full Image is 6 75 in width and 4 75 in in length and the Small Image is 3 75 in width and 2 75 in in length b Site List Displays a list of AURC...

Page 17: ...Size table in Technical Information e Record Setup File information for video and image setup A User define selection allows the addition of text before the date Long date time includes the full date...

Page 18: ...e left on the PC When the PC is full recording to the hard drive of the PC stops Recording on the AurorAcorD is not affected See Image Size table in Technical Information A message appears when the PC...

Page 19: ...p to NTSC 640 x 240 normal Clears all the user accounts and passwords user reverts to admin and password reverts vicon It is important to note that a result of using the PRESET button is that the next...

Page 20: ...in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Na...

Page 21: ...istance The larger cable results in a lower DC resistance and better video quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a...

Page 22: ...nt of cooling required for an installation Line Cord 12 VDC adapter cord supplied Radio Frequency Emission Rating FCC Class A Safety Standard UL 2044 COMPUTER REQUIREMENTS Hardware Minimum requirement...

Page 23: ...ow 2 2 Note Frames Sec 7 nominal in 640 x 480 Normal 15 nominal in 320 x 240 Normal Image Size Resolution Quality Image Size Kbytes Minimum 5 Low Typical 7 320 x 240 Maximum 9 or more Small Minimum 9...

Page 24: ...ECTORS AND INDICATORS Rear Panel Video Input BNC 1 channel Video Output BNC I channel auto termination Network Interface Ethernet RJ 45 Cat5e Serial Port RJ 45 Power DC jack Preset recessed button Sid...

Page 25: ...XX123 00 03 Rev 503 Network Interface Technical Information 17 Notes...

Page 26: ...ters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far...