Test Definition
140
© 1995-2005 Vibration Research Corporation. All rights reserved.
disables this limit. This safety limit prevents the drive output from increasing unless some response is
measured on the accelerometer. Refer to "
How to Tune Sine Controller Parameters
" for details on
how to determine a suitable value for your system.
The startup
Output Threshold
parameter defines the base output voltage on the control loop when a
test is starting.
The startup
Max Output
parameter
defines the maximum output voltage allowed from the control loop
when a test is starting. If the channel 1 drive signal output exceeds this value when starting a test, the
test will abort. We recommend setting this at about 150% of the normal start up voltage required.
The running
Max System Gain
parameter defines the maximum allowed ratio of output volts to
measured acceleration while a test is running. Setting this value to a large number (e.g. 100 volts/G)
disables this limit. This is a safety limit that restricts the drive output from increasing unless some
response is measured on the accelerometer. Refer to "
How to Tune Sine Controller Parameters
"
for details on how to determine a suitable value for your system.
The running
Max Output
parameter
defines the maximum output voltage allowed from the control loop
while the test is in Run mode. If the channel 1 output ever exceeds this value, the test will abort. We
recommend setting this at about 150% of the normal running maximum.
4.2.6
Channels tab
Sine Define Channels tab
Clicking the "Channels" tab in the
dialog box accesses this dialog box.
31
31
110
Summary of Contents for VibrationVIEW
Page 15: ...Document Revision Part I ...
Page 17: ...How To Part II ...
Page 96: ...Menu commands Part III ...
Page 142: ...Test Definition Part IV ...
Page 217: ...Control Centers Part V ...
Page 227: ...Accelerometer Toolbars Part VI ...
Page 231: ...Stop Codes Part VII ...
Page 263: ...Typical Views Part VIII ...
Page 268: ...VibrationVIEW Help 255 1995 2005 Vibration Research Corporation All rights reserved ...
Page 269: ...Dialog Boxes Part IX ...
Page 303: ...Windows Elements Part X ...
Page 309: ...APPENDIX Part XI ...
Page 311: ...APPENDIX 298 1995 2005 Vibration Research Corporation All rights reserved ...