Viavi T-BERD/MTS-580 Quick Manual Download Page 4

VIAVI//Public

T-BERD

®️

/MTS-5800 Handheld Network Tester

T-BERD

®️

/MTS-5800 Network Tester

QUICK  CARD

© 2021 VIAVI Solutions, Inc,
Product specifications and descriptions in this 
document are subject to change without notice.
Patented as described at viavisolutions.com/patents

Contact Us

To reach the VIAVI office nearest you, 

visit viavisolutions.com/contact

+1 844 GO VIAVI

(+1 844 468-4284)

RUN  TEST

1.

Tap the 

START

soft key         to start the test.

2.

The OCC will sweep the entire CWDM 
wavelength range.  Results will be shown in 
graphical and tabular formats as shown in 

Figure 8: Test Results

.

3.

Verify that traffic is on all expected channels, at 
the anticipated wavelengths and power levels, 
and that there are no unexpected wavelengths 
present.  

4.

Things to look for:

Every expected wavelength/channel is 
present.

Channels are about 20 nm apart.

Power levels of each channel are within 
roughly 3 dB of each other, or within the 
relative amplitude specification of the 
Network Equipment Manufacturer.

Figure 8: Test Results

FAST  REPORT

1.

Tap the 

Fast Report 

soft key         .

2.

Enter Cable ID, Fiber Number, Locations, and 
Direction.

3.

Tap 

Save 

.

4.

Tap       to accept the default filename and save 
test results.

5.

Tap the 

Fast Report 

soft key again to return to 

the results display.

6.

Tap       to return to the OTDR Home screen.

Figure 9: Fast Report

Summary of Contents for T-BERD/MTS-580

Page 1: ...t Requirements CWDM Optical Channel Checker This quick card describes how to connect to a fiber under test configure CWDM Optical Channel Checker OCC test setups run tests and analyze results with a T BERD MTS 5800 equipped with a COSA 4055 module Note The COSA module is used to monitor wavelengths on a live network Care should be exercised when unplugging fibers from the network as the fibers may...

Page 2: ... via a coupler during turn up or maintenance Figure 3 Connecting to Monitor Port Figure 4 Connecting to Common Cable 1 Inspect the OCC port on top of the test set 2 If connecting to the Common Cable connect the Common Cable to an optical coupler with the same connector type and inspect the fiber end face in the coupler 3 If connecting to the Monitor Port or Common Port on the Mux inspect the Mux P...

Page 3: ...to display the Setup menu 5 Tap Auto set to auto configure the OCC for a single sweep 6 Tap the Analysis tab If a splitter tap is used to access the signal set Splitter Value to the splitter loss in dB or LAUNCH TEST 1 Press the Power button to start the test instrument 2 Tap the Fiber Optics icon in the Status Bar at the top of the screen 3 If a purple symbol is displayed on the left screen side ...

Page 4: ...wn in Figure 8 Test Results 3 Verify that traffic is on all expected channels at the anticipated wavelengths and power levels and that there are no unexpected wavelengths present 4 Things to look for Every expected wavelength channel is present Channels are about 20 nm apart Power levels of each channel are within roughly 3 dB of each other or within the relative amplitude specification of the Net...

Reviews: