Run Test: 

1.

 

Tap the 

Real Time

 soft key 

 to start the 

test. 

2.

 

After auto-configuration, the OTDR will 
perform a connection check to ensure that 
the connection is 

Good

. If the Connection is 

Bad

, disconnect the launch cable, and 

reconnect as described on pages 1 and 2, 
cleaning every end-face that fails the 
inspection test. 

3.

 

The OTDR will perform real-time acquisitions 
at the configured wavelength.  

 

4.

 

Tap the magnifying glass icons to zoom in 

, zoom out 

, or auto-zoom 

 the 

display.  You can also pinch and zoom with 
your fingers. 

5.

 

Tap the 

Measurements

 soft key 

 to 

start Loss, ORL, or Reflectance 
measurements. 

 

6.

 

Tap the 

Test

 roll down menu at the bottom 

left screen to select a measurement type:  

Loss

ORL

, or 

Reflectance

  

 

7.

 

Tap and move the 

A

 and 

B

 cursors to change 

measurement values.  

 

Loss

 and 

ORL

 are measured between the 

two cursor positions. 

 

Reflectance

 is measured at the position 

of the 

B

 cursor. 

 

8.

 

Figure 10

 shows 

Loss

 measurement, 

Figure 

11

 shows 

ORL

 measurement, and 

Figure 12

 

shows 

Reflectance

 measurement. 

 

9.

 

Tap the 

STOP

 soft key 

 to stop the Real 

Time measurement.  

 

10.

 

Tap the 

Real Time

 soft key 

 to restart 

real time measurement. 

 

Figure 8: Expert OTDR 

 

 

Figure 9: Connection Check & Real-Time Acquisition 

 

 

 

Figure 10: Trace View, Loss Result 

 

 

 

Figure 11: Trace View, ORL result 

 

 

 

Figure 12: Trace View, Reflectance Result 

 