Chapter 5
Using LTE/LTE-A FDD Analyzer
Conducting RF measurement
SPA06MA-O User’s Guide
Page 88
22145360, R005
April 2021
Figure 39
LTE/LTE-A FDD channel power measurement
Occupied bandwidth
The Occupied Bandwidth measures the percentage of the transmitted power within a
specified bandwidth. The percentage is typically 99%.
Setting measure setup
After configuring the spectrum measurement in
“Configuring spectrum measurements”
, you can set the measure setup to continue your measurement.
To set measure setup
1
Tap the
Setup
(
) icon in the side bar.
2
Tap
Bandwidth
and select the value from the following choices:
1.4 MHz
,
3 MHz
,
5 MHz
,
10 MHz
,
15 MHz
, or
20 MHz
.
You can also tap the rectangle with value,(
) under
the chart screen and input the value using the on-screen keyboard.
3
Tap the
Center Frequency
(
)icon under the chart
screen to set the center frequency using the on-screen keyboard.
4
Tap
Menu
>
BW/AVG
>
Average
to set the number of measurements to be aver
-
aged using the on-screen keyboard.The input value range is from 1 to 100.
To set limit
1
Tap
Menu > Limit
.
NOTE
Channel Power measurement result shows channel power and spectrum den
-
sity in a user specified channel bandwidth. The peak to average ratio (PAR) is
shown at the bottom of the screen as well. The shaded area on the display
indicates the channel bandwidth.
Summary of Contents for SPA06MA
Page 1: ...SPA06MA O User s Guide R005 ...
Page 2: ......
Page 22: ...Chapter 1 Overview Module installation SPA06MA O User s Guide Page 6 22145360 R005 April 2021 ...
Page 410: ...Appendix A Physical specifications SPA06MA O User s Guide Page 394 22145360 R005 April 2021 ...
Page 412: ...SPA06MA O User s Guide 22145360 R005 April 2021 English ...