50
MPOLx-84/85 (P)
6 L
OSS
/L
ENGTH
T
EST
O
PERATION
D
EFINING
A
TEST
CONFIGURATION
Use the arrow keys to highlight a setup and press the center
button.
The Edit menu opens:
To select/deselect fibers for pass/fail testing
I
The instrument is in
Loss/Length
mode.
1.
Press the
[
A
]
key and tap the
[
Test Configuration
]
button.
The available test configurations are displayed.
2.
Tap and select an entry.
– or –
Use the arrow keys to highlight a setup and press the center
button.
The Edit menu opens.
Description
Description of the test configuration.
The description will be shown in the test configuration list below the
title.
Fiber/Light Source
Type
The fiber Type can be configured for
Single-Mode
or
Multi-Mode
measurements.
Test Limit
First select the limit specification/preset from the drop down menu.
Then edit the limit settings:
•
Expected Polarity:
Select the fiber connection type (see
).
•
Length:
Enter the length limit (to change the length unit see
change the length unit:” on page 46
).
•
Max. Loss:
at 1300 nm and 850 nm
Cable & Connector
Settings
Select the cable manufacturer, the cable name and the Connector Type
from the respective list.
See the indicated refractive Index.
Test Reference
Method
Select the reference method: 1 jumper cable or 3 jumper cables (for
).
Pass/Fail Fiber
Selection
Select/Deselect different fiber numbers for pass/fail testing.