Chapter 4
Power meter and Source functions on the OTDR test port
Storing and reloading results
86
User Manual
700MAN201 Rev. 002
2
On equipment (1) press
Laser START
.
Measurement using a mode conditioner
To perform an Insertion Loss measurement with a Source that is compliant to IEC
61280-4-1 Ed2 Standard on encircled flux, it is recommended to use a mode conditioner
after the OTDR Source port.
The light source and the mode conditioner has to be referenced together using the side-
by-side 1-jumper reference method (see
“Side by side reference” on page 84
1
Connect the Multimode source (1) to the mode conditioner
2
Connect the Powermeter port (2) to the jumper
3
Connect extremities of the mode conditioner and jumper to the fiber under test
using the appropriate method (ex. keying mechanism for FC/PC types).
4
On equipment (1) select
Laser START
to activate the light source.
Storing and reloading results
Report Setup
Press on
Setup
softkey, then
Report
:
File(s) save in
set the directory where the file(s) will be saved.
Figure 49
Measurement of the fiber under test
OTDR Module:
Source port
Mainframe
Power meter port
Fiber Under Test
Equipment (1)
Equipment (2)
Jumper
Figure 50
Measurement of the Insertion Loss with a mode conditioner
OTDR
Multimode
Source port
Mainframe
Power meter
port
Fiber Under Test
Equipment (1)
Equipment (2)
Mode
conditioner
Jumper
OTDR New IHM rev002.book Page 86 Jeudi, 5. mai 2022 11:50 11