11 Test Results
Dashboard
Displays the condition of the incoming
testing results when compared to the limits
configured in StrataSync.
Channel View
The Channel view provides a full scan view of the test
circuit with markers for the currently selected channel
and the frequency range displayed.
The Adjacent Channels graph indicates the selected
channel and its adjacent channels.
The Measurements table provides values for the
parameters under test, indicating their condition in
comparison to the configured limits.
Data values for the focused channel are provided for the
following:
QAM Channels
y
Level
y
MER
y
BER
y
BER
y
Echo
y
GD
y
ICFR
y
DQI