5.1.4 Tools: Fiber Inspection Tips and Cleaners
Fiber Type /
Connector
Tip(s) to use on
FiberChek/P5000i
Cleaning options
LC Fiber
Used at DU to
Hybrid
connection
and at the RU
side of tower
jumper.
Possibly on
CSR
FBPT-U12M
LC type IBC Cleaner (above) Cletop (below)
SFP/SFP+
In DU and RU.
Possibly on
CSR
FBPT-LC
Clean the TX side only if it has the same appearance as a
fiber (picture on far left). The RX side of SFP should not be
cleaned, just inspected to make certain there are no large
obstructions. Remove the entire aqua blue cap from the pen
to clean the SFP or a bulkhead (see below)
LC Bulkhead
or Patch Panel
FBPT-LC
ODC –
O
ut-
D
oor
C
onnector
Located at top
of the hybrid
to the RU
jumper cable
on Ericsson
To inspect ODC fibers, the BAP-3
Barrel assembly should replace
the BAP-1 barrel on the probe
and then the Male/Female
guides are used to align the
H125 type IBC Cleaner