Viavi MTS 2000 Quick Card User Manual Download Page 2

VIAVI//Public

T-BERD

®️

/MTS-2000 Modular Test Set

T-BERD

®️

/MTS-2000 Modular Test Set

QUICK  CARD

2

Optical Spectrum Analyzers. The Best OSA Modules & Platforms (viavisolutions.com)

CONNECT  TO  FI BER  UNDER  TEST  (FUT)

All fibers and connectors should be cleaned and inspected prior to connection, as described on page 1.  
The Nano OSA is typically connected to the FUT via a Monitor Port or splitter/tap to not disrupt service.  
The Nano OSA can also be directly connected to the common port or common fiber via a coupler during 
turn up or maintenance:

1.

Inspect the OCC port on top of the test set. 

2.

If connecting to the Common Cable, connect the Common 
Cable to an optical coupler with the same connector type and 
inspect the fiber end face in the coupler.

3.

If connecting to the Monitor Port or Common Port on the Mux, 
inspect the Mux Port.

4.

Inspect the fiber end face of the Patch Cable and connect the 
cable to the OCC port.

5.

Inspect the other fiber end face of the Patch Cable and Connect 
the Launch Cable to the coupler or Mux port.

Figure 3: OCC Port Inspection

Figure 4: Connecting to Monitor Port

Figure 5: Connecting to Common Cable

Summary of Contents for MTS 2000

Page 1: ...he Best OSA Modules Platforms viavisolutions com DWDM Optical Channel Checker This quick card describes how to connect to a fiber under test configure DWDM Optical Channel Checker OCC test setups run tests and analyze results with a T BERD MTS 2000 equipped with an OCC 4056C module Note The OCC module is used to monitor wavelengths on a live network Care should be exercised when unplugging fibers ...

Page 2: ...e common port or common fiber via a coupler during turn up or maintenance 1 Inspect the OCC port on top of the test set 2 If connecting to the Common Cable connect the Common Cable to an optical coupler with the same connector type and inspect the fiber end face in the coupler 3 If connecting to the Monitor Port or Common Port on the Mux inspect the Mux Port 4 Inspect the fiber end face of the Pat...

Page 3: ...ton to start the test set 2 Press the Home button to display the Home view with the OCC 4056c icon 3 Tap the OCC 4056C icon until it is yellow and highlighted Figure 6 Home Screen 1 Tap Setup icon 2 Tap Auto set to auto configure the OCC for a single sweep 3 If a splitter tap is used to access the signal Tap the Analysis tab and set Splitter Value to the splitter loss in dB or Figure 7 Setup Menu ...

Page 4: ...described at viavisolutions com patents Contact Us To reach the VIAVI office nearest you visit viavisolutions com contact 1 844 GO VIAVI 1 844 468 4284 RUN SWEEP TEST 3 Tap START icon upper right to run scan 4 View Results after scan completes Use your finger or stylus to scroll up down as needed Total of Channels detected Verify Channels Power Levels dBm Measure offset detect optics going bad Mea...

Reviews: