6 — © 2020 Viavi Solutions (8 Apr 2020)

 

 

7.

Press F4 to save your changes and to exit the BIOS setup.

The system automatically shuts down and restarts.

Now you can log on to the IPMI web interface and change the default
password.

8.

To change the default password, open a web browser to http://
<IpAddressOfIPMIport>, and log on with the user name ADMIN in
caps and <password>.

IpAddressOfIPMIport is the station IP address you configured in step
6. The password is located on a sticker that is affixed to the body of the
applicance. The sticker looks very similar to this one.

9.

Choose Configuration > Users, and select the second user account
(ADMIN account).

10. Click Modify User, and change the password.

11. (Optional) Set up alerts.

There is no audible alarm if there is an issue with a power supply unit.
Other alerting options are available. Each must be configured separately
using details from your environment.

To receive email alerts, change the settings at Configuration
SMTP.

To receive SNMP traps, change the settings at Configuration
SNMP.

To receive Syslog messages, change the settings at
Configuration > Syslog.

You configured the IPMI port and changed the default password. You may
have also configured your system to send alerts when certain situations arise.

How to configure the JBOD IPMI port

The JBOD chassis offers intelligent management with IPMI providing
hardware health monitoring and remote power control.

Prerequisite(s):   

Your host computer must be on the same network as the JBOD IPMI
interface. If necessary, change your host IP to 

192.168.1.10/24

.

 

JBODs must be monitored separate from any head unit. Like the head unit,
there is no audible alarm. You should set up alerts to notify you of any power
supply issues.

1.

Directly connect using your host computer to the JBOD IPMI port using
an Ethernet cable.

2.

On the host computer open a web browser to

http://192.168.1.99

, and log on with the user name ADMIN

and password ADMIN in caps.

If you have trouble connecting, see 

JBOD IPMI reset FAQ

.

3.

Make changes as needed, such as:

Change the ADMIN password

Change the network configuration to use DHCP

Set up alerts

Summary of Contents for GigaStor G4-60G-040-1152T

Page 1: ...G4 60G 040 1152T Hardware Installation 8 Apr 2020 ...

Page 2: ...20V Power dissipation watts 2143 Relative humidity non condensing 8 to 90 Temperature operating 10 C 35 C 50 F 95 F Temperature storage 40 C to 60 C 40 F to 140 F Compliance RoHS FCC CE 1 For SFP the SFP may be any of Copper 10 100 1000 1Gb SX LX For SFP the SFP may be any of 10Gb SR LR For QSFP the QSPF may be any 40Gb SR LR BiDi Universal For QSFP28 the QSFP28 tranceivers may be SR4 LR4 or BIDI ...

Page 3: ...ll or remove the appliance from the cabinet to perform any maintenance 1 Mount the head unit and all JBODs in your cabinet Refer to the instructions on VIAVI Rail Kit page 7 2 Connect the cables Power SAS Ethernet TAP Span IPMI optional 3 Insert the transceivers 4 Connect the KVM 5 Turn on the JBODs Caution JBODs must be turned on before the head unit The drives do not properly initiallize if the ...

Page 4: ...on the TAP c Use two analyzer cables to connect the analyzer port on the TAP to the SFP transceivers in the capture card d If you have more than one TAP to connect repeat the process for each TAP 11 Connect a monitor keyboard and mouse to the hardware appliance You can use a KVM switch if desired The KVM must be compatible with the operating system used on the appliance The user input devices or K...

Page 5: ...P address so you can disconnect them after the IP address is set The IP subnet and gateway or router addresses are available and known to you 1 Log in to the Windows operating system using the Administrator account and its default password admin You can change the Administrator account password after logging in See the Windows documentation if necessary 2 Select Internet Protocol Version 4 TCP IPv...

Page 6: ...tion SMTP To receive SNMP traps change the settings at Configuration SNMP To receive Syslog messages change the settings at Configuration Syslog You configured the IPMI port and changed the default password You may have also configured your system to send alerts when certain situations arise How to configure the JBOD IPMI port The JBOD chassis offers intelligent management with IPMI providing hard...

Page 7: ...ght side of the chassis and are labeled Both the front chassis rails and the rack rails have a locking tab which serves two functions First it locks the sever into place when installed and pushed fully into the rack its normal operating position In addition these tabs lock the server in place when fully extended from the rack This prevents the server from coming completely out of the rack when pul...

Page 8: ...e bottom rack first How to install the system into your rack Caution It is dangerous for a single person to off load the heavy chassis from the rack without assistance Be sure to have sufficient assistance supporting the chassis when removing it from the rack Use a server lift Caution Do not pick up the server by the front handles They are designed to pull the system from a rack only This section ...

Page 9: ...ard in the rack Technical Support Please contact technical support if your issues are not represented or you need further help North America 1 800 526 7919 South America 1 800 526 7919 EMEA 44 1 959 569 880 APAC 44 1 959 569 880 All Other Regions viavisolutions com contacts email nisupport viavisolutions com North South America uknisupport viavisolutions com EMEA APAC Support hours are 7 00 A M to...

Reviews: