5.14 Oscilloscope
The CX300 provides a basic Oscilloscope that can be used to evaluate an electrical signal
as it changes over time in order to examine waveform properties such as amplitude,
frequency, rise time, time interval, and distortion.
Practical uses of the Oscilloscope are:
•
Determining the frequency and amplitude of a signal assists with troubleshooting
and debugging a circuit's input and output for identifying a component
malfunction.
•
Identifying amount of noise in a circuit.
•
Identifying waveform shape.
The Oscilloscope can be viewed in default size, or as an expanded window. When the
Oscilloscope window is expanded, frequently used controls and settings are available on
the measurement window; other controls and settings are accessed from the Oscilloscope
test settings menus.
5.14.1 Oscilloscope Controls and Settings
The following controls and settings are used to configure the Oscilloscope.
Table 5-35 Oscilloscope Settings and Controls
Control/Setting
Description
Sweep
This field defines how quickly the trace sweeps across the
Oscilloscope screen. The sweep speed of an oscilloscope is
represented by time (seconds) per division.
Source
This toggle switch selects between a demodulated signal or an
audio signal as the trace signal source.
Audio In
Audio In
routes the incoming audio signal from the Audio
Input connector to the Oscilloscope. The audio input source
is selected in the Audio In pane.
Demod
Demod
routes the demodulated signal from the RF Input
connector to the Oscilloscope. The RF input source is
selected in the RF Receiver pane.
.
NOTE
Signal routing can also be configured on the
Audio Controls window
.