CT-X User’s Guide
22137813, Rev. 000
Feb 2020
33
Chapter
2 Setting up Your CT-X
System menu
The
CT-X
SYSTEM
menu is used to reset the CT-X unit to factory defaults and reset the user
name and password.
To change a setting in the menus, select
ENTER
to edit a setting, use
SELECT
to toggle the
setting, and then press
ENTER
to confirm and exit.
1. From the front panel of the CT-X, navigate to the
CT-X
SYSTEM
menu.
2. To reset the CT-X settings to factory default, select
LOAD FACTORY DEFAULTS?
Choose
SELECT
to confirm.
3. To reset the user name and password, select
RESET USER NAME AND PASSWORD?
Choose
SELECT
to confirm. The password will be reset to “admin”.
Status menu
The
CT-X
STATUS
menu allows you to see the application version information as well as
any errors.
From the front panel of the CT-X, navigate to the
CT-X
STATUS
menu, and view the status
from the following submenus:
ERRORS
– Shows any errors, invalid calibration or setup
PKG
– Shows the package version number
APP
– Shows the application version number
FPGA
– Shows the FPGA version number
WEB
– Shows the web interface version number