Chapter 11
Using EV-DO Signal Analyzer
JD700B Series User’s Guide
399
Figure 237 Multi-ACPR measurement with EV-DO signal analyzer
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See “Setting limit for RF tests” on page 401 for more
information.
Spurious emissions
Out-of-band emissions are unwanted emissions immediately outside the channel bandwidth resulting from
the modulation process and non-linearity in the transmitter but excluding spurious emissions. The Spurious
Emissions measurement is to identify and determine the power level of out-of-band spurious emission within
the necessary channel bandwidth and modulated signal measured at the RF port of the Base Station.
Setting measure setup
Procedure
1
Press the
MEASURE SETUP
hot key.
2
To set up the range table and frequency range, press the
Range Table
soft key and then
complete the following steps:
Press the
Range
soft key, and then enter the range number to add a new range or change
an existing one.
Press the
Enter
soft key.
Press the
Start Frequency
soft key to set up the frequency range.
Enter a value by using the numeric keys. You can also use the rotary knob.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
Press the
Stop Frequency
soft key to set up the frequency range.
Enter a value by using the numeric keys. You can also use the rotary knob.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
3
Toggle the
Range
soft key between
On
and
Off
to display or hide the selected range.
4
To set up the test limits for Pass/Fail indication, complete the following steps:
Press the
Start Limit
soft key.
Enter a value by using the numeric keys. You can also use the rotary knob.
Select the
dBm
soft key.
Press the
Stop Limit
soft key.