Chapter 10
Using CDMA Signal Analyzer
380
JD700B Series User’s Guide
Measurement example
Figure 225 Code domain power measurement with CDMA OTA signal analyzer
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication.
Setting display
You can view your measurement results in a different view option.
Procedure
1
Press the
TRACE/DISPLAY
hard key.
2
Press the
Code Order
soft key, and then select the code order option from the following choices:
Hadamard:
To assign the number based on Walsh code order and display the measured
code power according to the assigned number in sequence.
Bit Reverse:
Code number in binary bit is reversed relative to the Hadamard method.
3
Toggle the
Base Code Length
soft key and select the base Walsh code number:
64
or
128
.
Route map
The JD700B Series provides the Route Map function that allows you to collect data of points in an indoor or
outdoor environment and track the received signals and coverage of RF transmitters by plotting data real
time directly on top of a loaded floor plan or a map.
Setting measure setup
Procedure
1
If required, connect a GPS receiver to your JD700B series for outdoor mapping.
Indoor mapping does not necessarily need a GPS antenna.
2
Configure test parameters as described in the “Configuring test parameters” on page 352.
3
To load your map file, complete the following steps:
Plug in your USB drive that has a floor map or
.mcf
file type created in JDMapCreator. If