CellAdvisor 5G User's Guide
257
Setting measure setup
After configuring spectrum measurement in "
Configuring Spectrum Measurements
", you can set the measure setup to continue your
measurement. The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto
the instrument using the
Save/Load
icons on the side bar.
1
Tap the
Setup
(
)icon on the side bar.
2
Tap
Bandwidth
from the following choices:
5 MHz
,
10 MHz
,
15 MHz
, or
20 MHz
.
3
Tap to switch
Signal Tech Type
to
TDD
or
FDD
.
4
Tap
Mask Type
and select from the following options:
Wide Area BS A
,
Wide Area BS B
,
Local Area BS
, or
Home BS
.
The category is defined with base station type. Set Wide Area BS A/B for macro cell, Local Area Base Station for pico cell, and
Home Base Station for femtocell.
5
Tap
Menu
>
BW/AVG
>
Average
to set the number of measurements to be averaged using the on-screen keyboard.
The input value range is from 1 to 100.
Setting Limit
1
Tap
Menu
>
Limit
.
2
Tap to switch the
Test Limits
to
On
or
Off
to enable or disable Pass/Fail indication.
The result table color for Pass is green, and the result table color for Fail is red.
3
Optional.
Tap the
Save
icon on the side bar and select the save option form the choices available for your measurement mode.
Spectrum emission mask measurement with DSS Analyzer
If Lower Peak
or Upper Peak indicate Fail, the mask line becomes red.
ACLR
The Adjacent Channel Power Ratio (ACPR) designated by the 3GPP WCDMA specifications as the Adjacent Channel Leakage
Power Ratio (ACLR), is the power contained in a specified frequency channel bandwidth relative to the total carrier power. It may
also be expressed as a ratio of power spectral densities between the carrier and the specified offset frequency band.
Setting measure setup
After configuring spectrum measurement in "
Configuring Spectrum Measurements
", you can set the measure setup to continue your
measurement. The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto
the instrument using the
Save/Load
icons on the side bar.
Summary of Contents for CellAdvisor 5G
Page 1: ...1 CellAdvisorTM 5G User s Guide ...
Page 2: ......
Page 18: ......
Page 22: ......
Page 110: ......
Page 146: ......
Page 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Page 264: ......
Page 312: ......
Page 332: ......
Page 338: ......
Page 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Page 352: ......
Page 356: ...Appendix 344 ...
Page 357: ...345 ...
Page 358: ......