![Viavi Apex Enterprise G3-APEX-ENT-32T User Manual Download Page 353](http://html.mh-extra.com/html/viavi/apex-enterprise-g3-apex-ent-32t/apex-enterprise-g3-apex-ent-32t_user-manual_1011683353.webp)
Troubleshooting common issues
Chapter 16: Troubleshooting 353
Third, do not, under any circumstances, share interrupts, I/O ports, or memory
addresses between adapters. No matter what has worked before or what
might work in the future, sharing interrupts or memory settings is not a valid
configuration.
Troubleshooting checklist:
Does your network work without any Observer programs or drivers loaded? If
not, check your network installation instructions. After your network appears to
be running correctly, install Observer again. Try installing Observer on a different
system and see if you experience the same problem. This does not mean that
you will not be able to use Observer on the desired system. It may give you some
insight into the problem that you are having.
Troubleshooting a slow probe system
If a probe is overloaded, consider whether any of the following affect the
system. You can clear these one at a time to see if that resolves the system’s
issue.
Although all of the settings discussed in this section are configured in Observer ,
they are saved to the probe.
♦
A scheduled capture can be causing a system slow down. Determine if any
scheduled capture is occurring. On the
Home
tab, in the
Capture
group,
click
Live
>
Packet Capture
and then
Settings
>
Schedule
.
♦
Some extra processing happens when you have triggers and alarms
configured. Determine what alarms are enabled by clicking the Alarm
Settings button in the lower left.
♦
Are you running real-time Expert Analysis? Observer requires some
processing resources to get through the data, which could be a lot of data.
Real-time expert processes data as it is received. This requires continuous
processing of incoming data while the real-time expert is running.
♦
Are you collecting combined station statistics or protocol distribution
summary for your network? If so, these could be causing the system to
slow down. To determine if you are, click the
File
tab, and click
Options
>
General Options
. Scroll to
Startup and runtime settings
and clear these
settings, if necessary:
●
Collect combined station statistics at all times
●
Collect protocol distribution for the whole network
♦
Are you collecting network trending statistics? If so, is the sampling
divider less than 10? If so, increase the sampling divider to 10 or greater.
To determine your sampling divider, on the
Home
tab, in the
Capture
group, click
Network Trending
>
Network Trending
. Then click
Settings
>
General
tab. In the Collection Settings section, change the sampling
divider.
A probe is not connecting to the analyzer or vice versa
If the probe is not connecting, it could be one of several reasons. The log window
in Observer has useful information to give you an idea of why the connection is
failing.
Summary of Contents for Apex Enterprise G3-APEX-ENT-32T
Page 1: ...Observer GigaStor 17 2 0 0 User Guide 23 Feb 2018 ...
Page 85: ...GS 2P40 288T Chapter 1 Appliance installation 85 Figure 55 GS 2P40 288T Front ...
Page 93: ...GS 8P 576T Chapter 1 Appliance installation 93 Figure 59 GS 8P 576T Front ...
Page 100: ...GS 8P 288T 100 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 101: ...GS 8P 288T Chapter 1 Appliance installation 101 ...
Page 102: ...GS 8P 288T 102 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 103: ...GS 8P 288T Chapter 1 Appliance installation 103 ...
Page 104: ...GS 8P 288T 104 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 105: ...GS 8P 288T Chapter 1 Appliance installation 105 ...
Page 106: ...GS 8P 288T 106 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 107: ...GS 8P 288T Chapter 1 Appliance installation 107 ...
Page 108: ...GS 8P 288T 108 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 109: ...GS 8P 288T Chapter 1 Appliance installation 109 ...
Page 110: ...GS 8P 288T 110 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 111: ...GS 8P 288T Chapter 1 Appliance installation 111 Figure 64 GS 8P 288T Rear ...
Page 112: ...GS 8P 288T 112 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 113: ...GS 8P 288T Chapter 1 Appliance installation 113 ...
Page 114: ...GS 8P 288T 114 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 115: ...GS 8P 288T Chapter 1 Appliance installation 115 ...
Page 116: ...GS 8P 288T 116 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 117: ...GS 8P 288T Chapter 1 Appliance installation 117 ...
Page 118: ...GS 8P 288T 118 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 119: ...GS 8P 288T Chapter 1 Appliance installation 119 ...
Page 120: ...GS 8P 288T 120 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 125: ...GS 8P 288T Chapter 1 Appliance installation 125 ...
Page 126: ...GS 8P 288T 126 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 127: ...GS 8P 288T Chapter 1 Appliance installation 127 ...
Page 128: ...GS 8P 288T 128 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 129: ...GS 8P 288T Chapter 1 Appliance installation 129 ...
Page 130: ...GS 8P 288T 130 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 131: ...GS 8P 288T Chapter 1 Appliance installation 131 ...
Page 132: ...GS 8P 288T 132 GigaStor 23 Feb 2018 Archive Non authoritative version ...
Page 133: ...GS 8P 288T Chapter 1 Appliance installation 133 ...
Page 137: ...GS 8P 192T Chapter 1 Appliance installation 137 Figure 67 GS 8P 192T Front ...