ArcLight Hub User’s Guide
Component Operating Procedures
Rev. 001
1081006
5-45
It also displays a short status of the CDCs in the chassis. This
command takes one argument - verbosity:
•
0 - outputs the configurations of M&C, UC, and configuration
and short status of active CDCs only. This is the default
verbosity when none is supplied.
•
1 - outputs the configurations of M&C and UC only.
•
2 - outputs the configurations of M&C, UC, and configuration
and status of all CDCs. Eb/No target table is not outputted.
•
3 - outputs the configurations of M&C and UC only.
Table 5-8. MCD M&C ‘sd’ or ‘sky_dump’ Command – Parameter Descriptions.
Field
Description
Active LAN 1 IP address
Active M&C LAN 1 IP address
Active LAN 2 IP address
Active M&C LAN 2 IP address
Standby LAN 1 IP address
Standby M&C LAN 1 IP address (unused)
Standby LAN 2 IP address
Standby M&C LAN 2 IP address (unused)
NMS IP Address
SNMP traps are sent to this NMS IP address
NMS Port
SNMP traps are sent to this NMS port
RtNMS IP Address
UDP Link Status packets sent to this RTNMS IP address
RtNMS Port
UDP Link Status packets sent to this port number at RTNMS IP
address
RtNMS Log Port
Unused
MCD Spigot
0=reassembled packets are not transmitted from chassis
3=reassembled packets are transmitted on LAN 1
Congestion Control
Enabled – Enable congestion control processing
Disabled – Disable congestion control processing
Leader VCI
Uplink Power Control Leader VCI
VCI Minimum
Bursts with VCI below minimum are dropped
VCI Maximum
Bursts with VCI above maximum are dropped
Active M&C CP
Indicates Active M&C physical chassis slot number 8 or 9
Util. Card DVBN
Average of DVB center frequency after N samples (unused)
Util. Card DVB Data Rate
UC DVB symbol rate (unused)
Util. Card DVB CtrFreq
UC DVB center frequency in Hz (unused)
Util. Card Die Timeout
The time before Utility Card reboots itself if it does not get the M&C
poll (in seconds)
Util. Card Rsp Timeout
The time the M&C waits for Utility Card response (in seconds)
Util. Card Poll Rate
Rate at which M&C polls the Utility Card (in seconds)
Numer of CDCs detected
The number of currently active CDCs (active is booted up and ready
for traffic)
St
(Configuration) Chassis Logical Slot Number
H
(Status) CDC FPGA health - 0=dead, 1=loading, 2=fault, 3=not yet
configured, 4=idle, 5=demodulator ready, 6=detecting bursts
SelfTest
(Status) Self-test results - 80000000 = all pass, any other means
some failure has occurred
Actv
(Status) M&C view state of the CDC - -9=hot swap ready, 0=off, 1=PCI
detect in progress, 2=awaiting 1
st
health response, 3=sending
Summary of Contents for ArcLight
Page 2: ......
Page 3: ...ArcLight TM Hub User s Guide ViaSatDocument Number 1081006 Rev 001 ...
Page 4: ......
Page 5: ...ArcLightTM Hub User s Guide ...
Page 6: ......
Page 7: ...ArcLight TM Hub User s Guide ViaSatDocument Number 1081006 Rev 001 ...
Page 9: ......
Page 10: ......
Page 12: ...ArcLight Hub User s Guide iv 1081006 Rev 001 ...
Page 35: ...ArcLight Hub User s Guide Rev 001 1081006 xxvii ...
Page 36: ......
Page 64: ...ArcLight Hub User s Guide General System Description 1 28 1081006 Rev 001 ...
Page 70: ...ArcLight Hub User s Guide Initial Network Configuration 2 6 1081006 Rev 001 ...