52
Ventilator Y3 pellets
[%]
P 225
Setting the actual ventilator output for pellets as the fuel relating to 66% ventilator
output
Ventilator X4 pellets
[%]
P 226
It regards the percentage value of ventilator output
Value 100 represents 100% ventilator output and the actual ventilator output of
parameter 227 is assigned to this value. Note: This parameter cannot be changed
Ventilator Y4 pellets
[%]
P 227
Setting the actual ventilator output for pellets as the fuel relating to 100% ventilator
output
Ventilator slowing-down in the attenuation regime– pellets
[s]
P 228
Setting the ventilator slowing-down in the attenuation regime against the feeder
runtime in the attenuation regime
Ventilator output in the attenuation – pellets
[%]
P 229
Setting the ventilator output in the attenuation regime
Outside sensor deactivation
P 232
The value 0 – outside sensor deactivation; this deactivation can only be used in
case the QAA 88 device is as the space unit and then it regards the pure space
control.
The value 1 – active outside sensor
Note: The use of the outside sensor is recommended by the manufacturer
HC Diagnostics
P 233
The represented value serves for service purposes and current HC status
idenfification.
Boiler diagnostics
P 234
The represented value serves for service purposes and current boilerstatus
idenfification..
Restoration of manufacturer´s setting
P 235
The value 1 – activates the parameter and the manufacturer’s setting is restored.
Year
P 238
Settting the current year
Date
P 239
Settting the current date
Time
P 240
Settting the current time
6.3 QAA 88 device
The space or output water current temperature is displayed on
the display during the operation depending on the use of this device
(parameter P 28). The value is displayed in resolution 0,5
o
C. By
pressing the key
plus
or
minus
the desired temperature is
displayed.
The displaying cursor is in the lower part of the display and it
displays the current status of the device and ventilator. In case the
cursor is above
symbol (ON – OFF) the heat requirement is
ignored (ventilator and feeder do not run and other control and a
security elements are active). The device is switched on by means
of right-hand key ESC. The cursor jumps above the symbol
(description) Auto.
Fig. no. 23 QAA 88 device