Parameter
Description
Units
Set by the
manufacturer
Range
Resolution
P 220
Ventilator X1 pellets
[%]
0
0
0
P 221
Ventilator Y1 pellets
[%]
8
6 … 13
1
P 222
Ventilator X2 pellets
[%]
33
33
0
P 223
Ventilator Y2 pellets
[%]
16
11 … 21
1
P 224
Ventilator X3 pellets
[%]
66
66
0
P 225
Ventilator Y3 pellets
[%]
36
31 … 41
1
P 226
Ventilator X4 pellets
[%]
100
100
0
P 227
Ventilator Y4 pellets
[%]
46
41 … 51
1
P 228
Ventilator slowing-down in the attenuation
regime– pellets
[s]
3
1 … 60
1
P 229
Ventilator output in the attenuation – pellets
[%]
100
50 … 100
1
P 232
Outside sensor deactivation
1
0 … 1
1
P 233
Diagnostics HC
-
-
-
P 234
Diagnostics boiler
-
-
-
P 235
Restoration of manufacturer’s setting
0
0 … 1
1
P 238
Year
-
2000 - 2050
1
P 239
Date
-
01.01. – 31. 12.
Day
P 240
Time
-
00:00 – 23:59
Minute
6.2.1 Description of SAPHIR regulator parameters
Current outside temperature
[
o
C]
P 1
Current outside temperature displayed. The lowest displayed value of outside
temperature is -20
o
C.
Current boiler temperature
[
o
C]
P 2
Current boiler outlet temperature displayed.
Current heating circuit temperature
[
o
C]
P 3
Current heating circuit temperature displayed
Desired heating circuit temperature
[
o
C]
P 4
Current desired heating circuit temperature displayed
Current temperature HW
[
o
C]
P 5
Current HW temperature displayed
Desired boiler temperature in case of HW heating
[
o
C]
P 6
Current desired boiler outlet temperature in case of water demand on heating
displayed
Current warm water thermostat status
[
o
C]
P 7
Current HW thermostat status displayed
Current feeder temperature
[
o
C]
P 8
Current feeder temperature displayed
Current space temperature
[
o
C]
P 9
Current space temperature displayed
Current position of three-way mixing valve
[%]
P 10
Current position of three-way mixing valve displayed
Desired boiler temperature
[
o
C]
P 11
Current desired boiler outlet temperature displayed
Current ventilator output
[%]
P 12
Current ventilator output displayed