Page 56 of 85
viasis 3003 user manual
via
traffic
controlling
gmbh
Power on; 30.01.12;17:39:34
Firmware update; 30.01.12;17:39:09
Power on; 30.01.12;15:30:59
Power on; 30.01.12;15:29:35
Error USB; 30.01.12;15:29:25
Start of measurement; 16.12.11;16:52:10
Power on; 16.12.11;16:51:07
Error Xmodem timeout; 16.12.11;15:41:24
Start of measurement; 16.12.11;15:39:58
Power on; 16.12.11;15:35:10
<Continue with Return>
Each protocol entry is followed by date and time of occurrence.
After the output of the protocol you are prompted, whether the protocol shall be deleted or
not:
Delete data (y/n)?
As already mentioned you may erase the protocol, for an actual, continuous operation of the
log is this not necessary.
The size of the protocol message buffer depends on the size of the installed flash memory and
is for 2/4/8 MB storage 191/191/255 protocol entries.
6.5.2 Comment – text field
In the comment text field a text string with a length of 80 characters can be stored. In most
cases will this be sufficient to store information about the exact measurement location with
postal code, city, street and number and the measured lane direction.
The data of the comment text field are transferred in the header of the viasis measurement data
file (VTF file) and will be shown in the viagraph software in the comment field of evaluation
charts and spread sheets.
Allowed characters are alphanumeric characters, like letters, digits and punctuation marks, but
without question mark ‚?’ and colon ‚:’, because both characters are used in the viasis menu
control.
To delete the comment content enter <
Blank
> followed by <
Return
>.
6.5.3 System date and time
The date is to be entered with long year format after the choice
3
in the menu
Information
and time
. That means dates with year century digits from 01.01.2011 till 31.12.2099 are legal.
The viasis checks all date values within this range for correctness. Together with the date value
the actual day of the week must be set. The correct operation of the parameter set time sched-
ules (chapter 6.3.2) require a correct setting of the day of the week.
The system time can be set with the selection
4
in the menu
Information and time
to time
values between 00:00:00 and 23:59:59 o’clock.
Incorrect inputs as wrong separator characters, time or date values are rejected by a repetition
of the input prompt.