Page 51 of 85
viasis 3003 user manual
via
traffic
controlling
gmbh
headed international country dialing code. The phone number of the SMS recipient needs to be
entered without country code. Moreover the hints to legal text fields contents given in the
previous chapters 6.4.2.3 till 6.4.2.5 shall be observed.
If the “
SMS alarm
” is active, short messages for the events “
Battery voltage < 11,5V
”,
“
Memory > 95% full
” and “
System error
” are send within one minute after occurrence.
If you change the SMS configuration and respond “
y
” to the “
Send SMS (y/n)?”
question, you
should receive a test SMS with the content “
SMS delivery set!
”. If your computer is connected
by RS232 cable locally, the protocol of the SMS delivery is shown in the terminal window:
Send SMS...
AT+CSCA="+491710760000"
AT+CMGF=1
AT+CSMP=17,167,0,241
AT+CNMI=2,1,0,0,0
AT+CMGS="016312345678"
SMS ok
If the SMS delivery was successful the protocol is ended with “
SMS ok
” otherwise with “
Er-
ror SMS
”. Similar to the delivery of E-mails the delivery of SMS is delayed if you are
connected by GSM, Bluetooth or USB interface until this active connection is closed.
If you face problems with E-mail or SMS configuration or delivery and contact
our technical support, please provide the connection protocol as text or snapshot
attached to a send E-mail. The connection protocol is essential for a failure analy-
sis.
6.4.3 GPS Module (optional)
In case the viasis 3003 is equipped with a GSM/GPRS modem an additional GPS module for
the determination of the position of the viasis can be build in. The position data are determined
regularly and they are transferred as a position list to viagraph. The last position is also send in
the text of the viasis emails:
Information:
Viasis 3003 - Version 4.16
Serial number: 15SC9991
Active parameter set: 1
Interface options: Bluetooth, USB, GSM/Email, GPS
GPS: 20.09.15, 09:45:00, 51°03.5615',N, 007°00.9070',E
Date: 20.09.2015, Sunday
Time: 11:15:33
Number of values = 24274, Memory full: 6 % Battery voltage: 13,17 V
If you open a viasis measurement data file (*.vtf) with viagraph or you make a direct connec-
tion to a viasis with GPS module and click the
Tools
menu in the viagraph menu bar of the
Settings
window, see illustration 33, the menu item
GPS coordinates
is selectable.
If your computer is connected to the Internet and after a click to the
Tools
menu item
GPS
coordinates
viagraph will open your standard web browser with the Google Maps web site and
sends the viasis GPS coordinates.
The web browser shows then the map with the last viasis position, see illustration 47: