5.6.1 Overview compressed air regulator
The machine is connected to the external air supply via
a compressed air regulator. You can use this regulator
to monitor and regulate the pressure of the incoming
air.
The compressed air regulator is supplied with the
machine and needs to be mounted on the side of the
machine housing when installing the machine. The
regulator has the following connections:
n
1/8” internal thread, fitted with male compressed
air connector to connect the external compressed
air supply
n
6 mm push-in fitting to connect the machine.
NOTICE
Failure of the water separator
caused by a wrong alignment
of the compressed air regulator
The compressed air regulator must
always
be
mounted
in an upright position
because otherwise
the water separator will not work.
Mount the compressed air regulator in an upright
position.
On the left side of the machine are two bores which
you can use to mount the compressed air regulator on
the machine.
Mount the compressed air regulator in an upright
position, using the oval-head screws provided in the
bores.
F
IG
. 11 M
OUNTING THE COMPRESSED AIR REGULATOR
5.6.2 Installing the pneumatic hose
F
IG
. 12 I
NSTALLING THE PNEUMATIC HOSE
The blue compressed air socket must not be
confused with the stainless steel socket for
cooling liquid. Otherwise the machine will not
work properly.
1. Close the external compressed air supply valve.
2. Use the provided pneumatic hose to connect the
right
pneumatic connection of the compressed air
regulator to the pneumatic connection of the
machine.
3. Connect the external compressed air supply to the
left
pneumatic connection of the compressed air
regulator.
4. Thoroughly verify that all external pneumatic hoses
are properly seated in their corresponding con-
nections and that the hoses and connectors are
undamaged.
5. If all hoses and connectors are properly installed
and undamaged, open the external compressed air
supply valve.
Original Operating Instructions: S5
Version: 12/15/2021
S5 – Installing the machine