This  book  is  valuable.  In  addition  to  instructing  you 
on how to install and maintain your appliance, it also 
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep 
it with your other important papers.

This fireplace is approved for use as a wood burning 
fireplace or for use with a vented gas log approved to 

ANS Z21.60, Z21.84 or RGA 2-72 standards or for use 
with a vent-free gas log heater approved to ANS Z21.11.2 
standard. A vent-free log can only be installed in an af-
termarket (completion of sale, not for purpose of resale 
from  the  manufacturer),  permanently  located,  manu-
factured (mobile) home, where not prohibited by local 
codes. Approved hood must be installed when using a 
vent-free gas log heater (see 

Accessories

, page 18).

This firebox meets the construction and safety stan

-

dards of H.U.D. for application in mobile homes when 
installed according to these instructions.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

36" CirCulating louvered Firebox

oWner’S inStallation Manual

C36eMW-rb with brushed 

brass Finish bi-fold doors

C36eMW-rbb with black 

Finish bi-fold doors

C36eMW-rPlb with Platinum 

Finish bi-fold doors

Includes Manual 

Control Fan System 

and Combustion 

Air Kit

O-TL REPORT # 114-F-20-4

Summary of Contents for C36EMW-RB

Page 1: ...f termarket completion of sale not for purpose of resale from the manufacturer permanently located manu factured mobile home where not prohibited by local codes Approved hood must be installed when us...

Page 2: ...ustment alteration service or maintenance can causeinjury propertydamageor loss of life Refer to this manual for assistance or additional in formation Consult a qualified installer or local distributo...

Page 3: ...replace Opening for Outside Air Left or Right Side Application Firestop Thimble 91 2 27 Fireplace Installation selecting location To determine the safest and most efficient location for the fireplace...

Page 4: ...feet This measurement includes fireplace chim ney sections and height of termination assem bly at level of flue gas outlet see Figure 3 For manufactured home application minimum height is 11 for strai...

Page 5: ...o fit your required platform height Ember protector should extend under fireplace a minimum of 1 1 2 The ember protector should be made of metal material 6 Using screws or nails secure fireplace to fr...

Page 6: ...make all necessary connections 4 Place all wiring connections into electric housing as shown in Figure 7 5 Secure electrical cover plate with screws previously removed 6 Tighten strain relief plastic...

Page 7: ...mating hole next to opening and secure with screws removed from cover plate in step 1 6 Install outside air vent termination in a location that will not be obstructed by bushes snow etc Locate vent n...

Page 8: ...pulling chimney upward after locking Chimney will not come apart if properly locked It is not neces sary to add screws to keep chimney together exception see Figure 16 page 11 Adjustable Firestop Thim...

Page 9: ...12 A6 12 pitch means that the roof drops 6 for each 12 measured horizontally down from roof rafters 3 Use roof opening chart Figure 13 to determine correct opening length and flashing required 4 Remov...

Page 10: ...desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart and Figure 14 OFFSET CHART 22 50 FT SYSTEM HEIGHT Figure 15 Ceiling Support Pipe 12S 8DM S...

Page 11: ...er with Living Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Flashing installation v6f 8dm or v12f 8dm Determine the flashing to be used with the roof opening c...

Page 12: ...vertical height difference of 18 see Figure 21 24 Min 24 Min 18 Min Typ Figure 21 Multiple Chase Installation Figure 19 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Fireplace syste...

Page 13: ...or a qualified service person Note Before you proceed make sure your gas supply is turned off A gas line may be installed for the purpose of installing a vented or vent free appliance available throu...

Page 14: ...LI FIED SERVICE PERSON Note Secure incoming gas line to wood fram ing to provide rigidity for threaded end If you wish to install an unvented vent free gas log set ONLY UNVENTED GAS LOG SETS WHICH HAV...

Page 15: ...Glass Doors Glass doors are standard with fireplace When fireplace is in operation doors must be FULLY OPENED or FULLY CLOSED position only or a fire hazard may be created see Figure 27 A fireplace eq...

Page 16: ...htly loosen lower pivot clips and upper spring clips Replace doors and fully close them Use 1 8 shims any material to level doors Once proper setting is achieved carefully open doors enough so that yo...

Page 17: ...20030 Front Bottom PN 21242 Rear Bottom PN 21241 Optional Outside air kit for floor installation 90154 Model AK6E Replacement Parts Technical Service You may have further questions about instal latio...

Page 18: ...ews Cable Ferrule Eye Bolt Screw Strand Wire 50 ft 30 Offset and Return 30E 8DM Adjustable Hood GA6053 Antique Brass Finish GA6052 Polished Brass Finish GA6050 Black Painted Finish This hood is requir...

Page 19: ...t Kit Description MW8K 8 Vent Kit MW9K 9 Vent Kit 36 8DM 36 Double Wall Pipe 2 2 24 8DM 24 Double Wall Pipe 1 0 18 8DM 18 Double Wall Pipe 0 2 FST A Adjustable Firestop Thimble 1 1 V6F 8DM Roof Flashi...

Page 20: ...DESA Heating LLC 2701 Industrial Drive Bowling Green KY 42101 www desatech com NOT A UPC 110746 01 Rev P 07 08 110746 01 This fireplace is manufactured for Stylecrest Inc under the VEXAR brand name by...

Reviews: