Waste water control panel WWCP
Setting the ‘Level changing time’
• Press the
key repeatedly to move through the possible set-
tings.
The set value will be shown by one of the ‘Tank level’ LEDs.
• Press the
key.
Explanation:
If the level in the tank does not change by 2% within a set time of ac-
tivating the pump cycle, the pump cycle will be stopped and an alarm
will sound. If the level does not drop, this can mean that the pump is
blocked.
The tank level LEDs show the finishing times:
100%
50%
75%
25%
100%
50%
75%
25%
100%
50%
75%
25%
2,5 min
5 min
10 min
OR
Press the
key
to bypass setting
the ‘Level chang-
ing time’.
B
Continued from previous page.
C
Continue on the next page.
5
Technical specifications
Power supply
: 12 or 24 Volts
Power consumption (standby)
: 4 mA
Max. power consumption
: 100 mA
Input:
For level sensor
: 0 - 300 ohm (0 ohm = full, 300 = empty)
e.g. Vetus WWSENSORA or SENSORA
Outputs:
For waste water pump
: max. power consumption 10 A
For electrically operated shut-off valve : max. power consumption 5 A
For WC / Alarm
: max. power consumption 1 A
Dimensions
: 85 x 85 mm (3
3
/
8
” x 3
3
/
8
”)
Build-in depth
: 78 mm (3
1
/
16
”)