background image

Manual 

MANUAL ERT DYNALINK 

With optional remote display 

Nordens största webbshop för vågar 

Hantverksvägen 15, 

76493

 Väddö, Sverige

Tel.

 +46 (0)176-208920  

Web     www.vetek.se 
Email 

  [email protected]  

Manual_ERT_V

2

Summary of Contents for DYNA-LINK ERT Series

Page 1: ...1 Manual MANUAL ERT DYNALINK With optional remote display Nordens största webbshop för vågar Hantverksvägen 15 76493 Väddö Sverige Tel 46 0 176 208920 Web www vetek se Email info vetek se Manual_ERT_V2 ...

Page 2: ...d display 5 2 Key area 5 CHAPTER 3 WIRELESS INDICATOR OPERATION GUIDE 7 CHAPTER 4 DYNA LINK FUNCTION GUIDE 8 1 Turn on off 8 2 Zero 9 3 Tare 9 4 Peak Hold 9 5 Accumulation 9 6 Accumulation Search 9 7 Accumulation Clear 9 8 Battery Voltage Check 10 9 Unit Convert 10 CHAPTER 5 PARAMETER SETTING CALIBRATION 10 1 Parameter setting 10 2 calibration 13 CHAPTER 6 SIGNAL ILLUSTRATION 14 CHAPTER 7 TROUBLES...

Page 3: ...ERT wireless Dyna link load guage is an extremely well built instrument for industry use as a standard wireless tool offer universal applications Whether used as conventional crane weigher or to measure force ERT wireless Dyna link load guage is microprocessor controlled for precision accuracy calibration is easier with wireless indicator 1 Standard Features Rugged construction Accuracy 0 1 of cap...

Page 4: ...al Wireless Frequency 2 4GHz default 433MHz 860MHz optional 3 Specification MODEL Max capacity kg lb Min weigh kg lb Division kg lb Total display counts n ERT 01 1000 2200 10 20 0 5 1 n 2000 ERT 02 2000 4400 20 4 0 1 2 n 2000 ERT 03 3000 6600 20 4 0 1 2 n 3000 ERT 05 5000 11000 40 8 0 2 4 n 2500 ERT 10 10000 22000 100 200 5 10 n 2000 ERT 15 15000 33000 100 200 5 1 0 n 3000 ERT 20 20000 44000 200 4...

Page 5: ...0000kg 465 150 104 305 184 930 Steel 100000kg 570 190 132 360 229 1230 Steel 200000kg 725 265 183 440 280 1380 Steel 5 Power supply Battery LR6 AA size alkaline batteries 1 5Vⅹ3 Current the Dyna link load guage average current is about DC 25mA 3pcs new batteries can be used for about 50hours wireless indicator average current is about DC 20mA 4pcs new batteries can be used for about 80hours Low ba...

Page 6: ...alue is Peak Hold value maxmium value e MEM Appear one time when Parameter or calibration value storage long time appearance means current value is Accumulation data f STB Stable Status g kN kilonewton N Newton Tare status N will flash h t ton i lb pound j kg kilogram 2 Key Area a ON OFF Power ON Power OFF 1 Press ON OFF Key 3 Second the Dyna link load guage turn ON 2 In ON status Press ON OFF Key...

Page 7: ...DICATOR OPERATION GUIDE ZERO a In testing status there are small digits on screen press this key to obtain the zero reading b In Parameter Setting status it Used as scrolling up TARE a Hang sling or container on the hook when the reading stable press this key the digits display 0 and N indicator Flash b Put the goods into container the DYNA LINK will display goods net weight c If move goods and co...

Page 8: ...y again back to test mode Press MODE key 7 times display clEAr Press ENTER Key access Accumulation clear Status display CLr Press ENTER Key again display noCLr press MODE key again back to test mode Press MODE key 8 times display CLIBr Press ENTER Key 3 seconds access calibration Status if press ENTER key less than 3 seconds it will back to test mode Press MODE key 9 times display dFuLt Press ENTE...

Page 9: ...t accumulation time H Front four digits of total value L Rear four digits of total value After display above contents twice the DYNA LINK will return automatically 6 ACCUMULATION SEARCH OPERATION DISPLAY ILLUSTRATION Press MODE key 6 times Then Press ENTER Key No Current accumulation time Current weight reading H Front four digits of total value L Rear four digits of total value Press MODE key aga...

Page 10: ... ILLUSTRATION Press MODE key select UnIt press ENTER key Un 00 press ENTER key Unit will be changed circulate Press MODE key again Return 10 Return to normal tecting status OPERATI ON DISPLAY ILLUSTRATION Press MODE keyselect ESC press ENTER key Return to normal tecting status HAPTER 5 PARAMETER SETTING CALIBRATION You can use wireless indicator to operate parameter setting and calibration 1 Key f...

Page 11: ... 0 Press ENTER to confirm Ab 24 Display zero range A zero range by hand B zero range automatically 0 5 total 6 options 0 0 F S 1 2 F S 2 4 F S 3 10 F S 4 20 F S 5 50 F S Generally Don t change this parameter Press ENTER to confirm Cd 11 New Dyna link the screen display Cd 11 if Dyna link calibrated the screen display calibrated value Press ZERO to confirm Cd 11 C zero tracking range 0 5 total 6 op...

Page 12: ...s ENTER to confirm 1 OFF New dyna link the screen display 1 OFF if dyna link calibrated the screen display calibrated value Press ZERO to choose 1 LO Choose Set point 1 mode 1 OFF means set point 1 no function 1 LO is Set point 1 lower 1 HI is Set point 1 High Press ENTER confirm 02000 New dyna link the screen display 02000 if dyna link calibrated the screen display calibrated value Press ZERO to ...

Page 13: ... Cap 2000kg Dyna link as example pay attention that the screen display 0 after hanging tare weight you can hang tare weight at first then turn on Press MODE key 8 times display CLIBr Press ENTER Key 3 seconds access calibration Status LoAd No load the screen display 0 and wait until STB display Hanging standard weight 2000kg Waiting until STB signal on screen Press ENTER Key 02000 Display capacity...

Page 14: ...t L Rare four digit of accumulated weight Total weight front four digit rare four digit CLr Ask if you really want to delete accumulated weight In case error deletion noCLr Give up deletion 88888 Confirm deletion Input value is too large When you input tare or weight value Input value is too small When you input tare or weight value noACC No any accumulated content when you check accumulation oL0 ...

Page 15: ...battery Display doesn t respond to load changes Faulty loadcell or PCB Requires authorized service Out of calibration Re calibration Display experiences excessive Zero drift between weighment DYNA LINK do not stabilize after turning on After turning on heating 3 5 minutes Displayed weight shows large error DYNA LINK not Zeroed before applying weight Depress ZERO before applying weight Requires rec...