Operation. 

At the beginning of every shift, inspect the perimeter toe guard for correct operation. First raise the platform. 

Push and hold a section of the perimeter toe guard up against the platform. The platform should not move when 

the “LOWER” button is pressed. Perform this check on all four sides of the platform. 

Check the condition of the guards, controls, scissor mechanism, hydraulic lines, and limit switches. If any item 

is in need of repair or otherwise contributes to an unsafe condition, remove the lift table from service until it is 

restored t

SATISFACTORY CONDITION

. See 

RECORD OF SATISFACTORY CONDITION

.  

Carefully push the table to the desired location. Only travel over even, level, improved surfaces capable of 

supporting the weight of the table plus a full capacity load. Apply both caster brakes whenever the table is 

stationary. Both brakes must be applied whenever the tabletop is raised or lowered.  

Each standard EHLTP portable  scissor lift table  includes  an electric-hydraulic power unit and a handheld 

pushbutton controller. 

  Press the “RAISE” pushbutton to energize the power unit and raise the platform. The 

platform rises only while the pushbutton is pressed. When the pushbutton is released, 

the platform will stop and hold its position. At the platform’s maximum height, a limit 

switch prevents the platform from further raising.  

  Press the “LOWER” pushbutton to open the hydraulic valve and lower the platform. The 

platform descends by gravity, i.e. the pump motor does not run. Release the pushbutton 

to stop the descent. The platform will maintain position until either pushbutton (RAISE or 

LOWER) is pressed. If the perimeter toe guard encounters an object, the valve will close 

and prevent further descent of the platform. 

 

  Hydraulic overload protection prevents the power unit from attempting to raise a load that exceeds the capacity of 

your table.  

  Lowering speed is preset at the factory and cannot exceed 30 fpm. In the event of a hydraulic system failure, e.g. 

ruptured hose, a velocity  fuse  activates  and  prevents  the platform from lowering.  The fuse is integrated into the 

lifting cylinder. 

 

 

Always watch the area around the platform as well as the load on the platform when the 

table is operating.

 

 

Never use the lift table if any damage or unusual noise is observed, if it is in need of repair, 

or if any other malfunction is observed. Immediately remove it from service and notify your 

supervisor or maintenance personnel about the issue(s) you observed. 

 

Keep all personnel clear of the machine when it is in operation. Before operating the lift 

table, make certain no part of any person or object is under the platform. 

 

Guards shall be in place before operating the lift table.

 

 

Guards cannot protect against every possible condition  and should not be considered a 

substitute for good judgment and care in use, loading, handling, storage, etc. of the lift 

table.

 

 

INSPECTIONS AND MAINTENANCE 

Regular  maintenance is essential for maximizing the service life of this product. Compare all inspection 

results to the 

RECORD OF SATISFACTORY CONDITION

. 

The table should only be used if it is in satisfactory 

condition. If an inspection reveals any changes from satisfactory condition, repair it before returning it to service. 

Only use manufacturer-approved replacement parts. DON’T GUESS! Contact 

TECHNICAL SERVICE

 if you have 

questions that are not addressed in these instructions or if you are uncertain how to address an issue discovered 

during an inspection. Technical Service can be contacted by calling (260) 665-7586 and asking for the Service 

and Parts Department or by submitting your questions through Vestil’s online parts and service portal at 

https://www.vestil.com/page-parts-request.php

. 

 

 

Identify all potential hazards and apply relevant safety procedures before beginning work.

 

 

Remove any load and install the maintenance props before beginning any inspection or 

service on the lift table.

 

Only qualified individuals trained to understand mechanical devices, electrical and hydraulic circuits, and the 

hazards associated with them, should attempt troubleshooting and repair of this equipment. 

 

Before inspecting or performing maintenance on this lift table: 

  Remove the load from the platform. Do not attempt to service a loaded lift table. 

Summary of Contents for EHLTP-4864-2-60-D2

Page 1: ...replacement parts labels and accessories call our Technical Service and Parts Department at 260 665 7586 The Department can also be contacted online at https www vestil com page parts request php Elec...

Page 2: ...Label 287 as shown in LABELING DIAGRAM on p 11 Also see SPECIFICATIONS on p 5 Handle only stable and safely arranged loads within the capacity of the cart DO NOT allow people to stand or sit on either...

Page 3: ...manufacturer approved replacement parts Order replacement spare parts for this equipment by contacting the TECHNICAL SERVICE DEPARTMENT DO NOT use brake fluid or jack oils in the hydraulic system If o...

Page 4: ...E F ZINC 1 1 16 99 021 901 001 HYDRAULIC CYLINDER 3X 10 RAM STYLER 1 1 17 33444 MACHINE BUSHING 1 18 GA 2 1 18 20 117 003 EXTERNAL RETAINING RING 1 DIA SHAFT 2 1 19 36209 13 HEX JAM NUT PLAIN 1 2 24 5...

Page 5: ...4 12 33004 FLAT WASHER USS ZINC PLATED 1 4 8 13 24189 8 32 FHSCS 2 14 01 015 017 TOE GUARD LIMIT SWITCH ACTUATOR 2 Item attaches separately to platform Item attaches to base SPECIFICATIONS Documents t...

Page 6: ...dels are suitable for indoor use in most non classified industrial locations as well as many commercial locations Only lift stable evenly distributed nonhazardous loads having a size or footprint appr...

Page 7: ...ystem failure e g ruptured hose a velocity fuse activates and prevents the platform from lowering The fuse is integrated into the lifting cylinder Always watch the area around the platform as well as...

Page 8: ...table for 1 Adequate oil level The oil should be 1 to 1 below the reservoir fill hole with the platform in the fully lowered position See the Annual Inspection section for the hydraulic oil specifica...

Page 9: ...alve body see illustration below 11 Reinstall the solenoid valve Tighten to 20 ft lb of torque Reattach the solenoid coil and the retaining nut BLEEDING AIR FROM THE HYDRAULIC CYLINDER Air can enter t...

Page 10: ...r due to power wire size too small wire run to long or incoming voltage too low Check the power installation for adequacy Check the incoming voltage while the motor is running Correct any problems fou...

Page 11: ...the unit when you first receive it as discussed in the RECORD OF SATISFACTORY CONDITION section of this manual Make sure that your Record includes a photograph of each label Modify this diagram if nec...

Page 12: ...rs hydraulic pumps motor controllers and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batter...

Reviews: