12
OPERATING INSTRUCTIONS
Read all instructions before operating the C20v.
1.
Select Vacuum Pouch
Select the proper size vacuum pouch. Allow a minimum of 1” to
2” of extra headspace at the top of the pouch to ensure a
quality, air-tight seal.
2.
Plug machine into grounded electrical outlet.
The LED on the control panel will read “OFF” and be in Power
Save mode.
3.
Turn power switch to “On”
When the chamber lid is open, the LED display will show the last
setting for vacuum time, sealing time, or cooling time. If reusing
these settings, place the filled vacuum bag into the chamber
and close the chamber lid. The machine will start automatically.
When the chamber lid is closed, LED display will show “CLO”.
NOTE: When the LED display shows “CLO”, the machine is in
protection mode. In this mode, no matter which button you
press, the machine will not operate. Open the chamber lid
to return to normal operation.
4.
Adjust / Set Timing Controls
Vacuum Time: With the lid open, press the “Set” button until the
indicator light next to Vacuum is on. Press “
∧
” or “
∨
“ button
to increase or decrease vacuum time. For the initial test, set
the vacuum time to 30 seconds. Adjust vacuum time
accordingly to achieve the vacuum required. Depending
on the pouch size and the amount of product in the
package, the vacuum time can vary from 5-90 seconds.