■Operation
4) When the N-3 is activated, the top part will glow in green and ion will be generated.
* Please turn off the unit when air supply is stopped.
* Takes around 60 seconds until ion generation is stable after switching on.
Air Control
Air output has to be controlled by external equipment like
an electro valve or a foot valve.
* The screw plugs at the sides of N-3 can be removed
with a key wrench (5mm) so that the air inlet can be set
at either side. Please refer to the illustration.
1) Connect an air hose (φ6.0 x φ4.0 mm) to the air inlet of
N-3.
2) Air pressure should be adjusted within the range between 0.1
and 0.6 MPa with an appropriate air regulator.
* Ion balance fluctuates according to air pressure and
volume in use.
* Lower air pressure is recommended for semiconductor
material sensitive to static electricity.
3) Supply dry clean air without moisture in the air.
* Moisture interferes with corona discharge on the electrode needle.
4) Supply power and direct the ionized air toward the work piece.
5) When static elimination is completed, turn off the power and air supply.