![Vess R2000 SERIES Product Manual Download Page 651](http://html.mh-extra.com/html/vess/r2000-series/r2000-series_product-manual_1008893651.webp)
624
Vess
R2000
Series
Product
Manual
Promise
Technologies
O
verheAting
Overheating is a potentially serious condition because the excessively high temperatures can lead to physical
drive failure and controller malfunction.
Overheating usually results from:
• Fan failure
• Inadequate air circulation around the enclosure
See
“Replacing a Power Supply” on page 539.
Inadequate Air Circulation
Air circulation around the Vess R2600 enclosure might be a more complex problem. Use the thermometer icons
to help you locate the specific hot spot. Check for these conditions:
• Accumulated dust or objects blocking the fans
• Less than a minimum of 13 cm (5 inches) space between the back of the enclosure and the wall or other
object
• Ambient temperature above 35°C (95°F) where the subsystem is operating
• Failed Cooling Unit
To cool down an enclosure:
• Correct any problems identified above.
• Power it down and let it sit for an hour or longer.
If a Cooling Unit must be replaced, do not remove the failed unit until a replacement unit is available. A hole
on the back of the enclosure created by a missing Cooling Unit affects air circulation which will cause controller
units to overheat and shut down. If a replacement Cooling Unit is not available, leave the failed unit in place until
Important
In the event of a Cooling Unit failure,
DO NOT
remove the failed unit until
there is a replacement available and on hand. A single functioning Cooling
Unit is adequate for cooling the system as long as the failed Cooling Unit
remains in place. Removing the failed unit without replacing it will adversely
affect airflow within the enclosure resulting in critical overheating and
shutdown of the enclosure.
Summary of Contents for R2000 SERIES
Page 1: ...ProductManual ...
Page 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Page 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Page 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Page 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Page 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...