For FC & iSCSI systems, you can set up an Initiator LUN map.
You can set up the LUN map type on the same subsystem but only one LUN map type can be active at a time.
A maximum of 256 logical drives can be mapped to an FC initiator or to an iSCSI initiator.
To assign a LUN to an FC or iSCSI initiator, add the initiator first. See
“Adding an Initiator (CLU)” on page 499.
LUN mapping must be enabled in order to map a LUN. See “Enabling LUN Mapping (CLU)” on page 498.
M
APPing
A
lun
tO
An
fc i
nitiAtOr
To map a LUN to an FC initiator:
1. From the Main Menu, highlight
Additional Info and Management
and press
Enter
.
2. Highlight
LUN Mapping
and press
Enter
.
3. Do the following actions:
• Highlight
LUN Mapping: Initiators
and press
Enter
.
Then highlight an initiator and press
Enter
.
A list of logical drives displays.
4.
In the LUN field, press the backspace key to erase the current value, then type the LUN you want to
assign to this initiator, from 0 to 255.
Each logical drive can have only one LUN and must have a unique LUN.
If you make a error, press
Control-AR
to restore the current LUN.
5. Press
Control-A
to save the LUN map.
Summary of Contents for R2000 SERIES
Page 1: ...ProductManual ...
Page 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Page 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Page 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Page 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Page 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...