FALA100/12V/TR

12V Bathroom Extract Fan

VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: [email protected] web: www.ves.co.uk

Original Instructions : Installation, Operation & Maintenance Manual

 

ID Ref 915

 August 2014

Original Instructions : Installation, Operation & Maintenance Manual

Original Instructions : Installation, Operation & Maintenance Manual

This manual must be read in full before Installation, Operation and
Maintenance of the units supplied. Please ensure that this document is
passed to the end user. This manual forms an integral part of the product
and should be kept for the working life of the product. Additional copies of
this and supporting documents are available by contacting VES or by
visiting www.ves.co.uk and following the 'Download O & M's' link.

IMPORTANT

The following symbols used within this document refer to potential dangers
or advice for safe operation

Indicates hazards associated with electric current and high
voltages

Indicates hazards that require safety advice for personnel
and/or potential unit/property damage

Indicates important information

fans are suitable for installation in Zone 1 and beyond the

zoning area (see below) The transformer

be located beyond ZONE 2.

IMPORTANT

MUST

All FALA fans must be sited and installed in accordance with current IEE
Regulations BS7671 and the appropriate Building Regulations.
FALA100/12V/TR

FALA100/12V/TR is suitable for wall mounting only.
The fan should be installed in conjunction with an appropriate mounting kit
and consideration must be given to ensure that access to all moving parts of
the fan are restricted when the fan is in use.

Unit Description

The

axial fan is suitable for bathroom extract applications;

for full unit details please see the unit specification later in the document.

Immediately upon receipt of your

fan, check there is no

damage to the fan, and that the four fixing screws and matching wall plugs
are included within the ancillary bag. Also included is a 12V transformer
part number DMEL1010.
In the event of any damage having occurred or if any item is found to be
missing, it is essential to inform VES Andover Ltd. within 7 days of delivery
quoting sales order number and the unit type.  After this period, VES would
be unable to accept any claim for damaged or missing goods.

FALA100/12V/TR

FALA100/12V/TR

FALA100/12V/TR ...............................12V extract fan c/w transformer

Part Number

Description

Dimensions

A

B

C

D

Ø

E

F

G

(mm)

FALA100/12V/TR
DMEL1010

157

157

20

56

98

-

-

-

(Transformer)

-

-

-

-

147

86

66

A

B

C

D

Ø

1

zone

0

zone

2

zone

2

zone

2

zone

600mm

600mm

600mm

2250mm

IMPORTANT

Before attempting to carry out any work on our units, all accompanying
documentation including warning labels on the unit must be referenced.
Should it be necessary to remove any component ensure that these are
secured into position once reinstalled. It is critical that after any
maintenance work has been conducted that all components removed
/replaced be refitted correctly by a competent engineer.