8200 -48 VDC Power System
System Application Guide
Spec. No: 582140000
SAG582140000
Model Nos: 802
NLDB
, 802
NLEB
, 802
NL
-
B
,
Proprietary and Confidential © 2022 Vertiv Group Corp.
Revision BH, September 28, 2022
8200
NLDB
, 8200
NLEB
and 8200
NL
-
B
Page 22
♦
In ferro replacement applications, will accommodate ten (10) AC inputs sized for 200 A ferro rectifiers (208 V, 60 A or
480 V, 25 A).
♦
List 5: Equipped with an MCA Assembly and provides mounting for optional LMS Main CPU circuit card. Provides a
seven-slot card cage for mounting MCA customer alarm relay circuit cards, MCA I/O circuit cards, and/or optional LMS
I/O circuit cards. Two (2) MCA customer alarm relay circuit cards provided.
♦
List 105: Equipped with an NCU controller and front panel touch screen PC for local access to the NCU webpages.
Includes an IB4 board which provides a Network connection point for NCU remote access. Includes the IB2 NCU
interface board (provides eight (8) programmable form C- relay outputs, eight (8) programmable binary inputs, and two
(2) temperature inputs). Includes the EIB NCU extended interface board (provides five (5) programmable form-C relay
outputs, two (2) temperature inputs, three (3) shunt inputs. and eight (8) battery midpoint inputs).
♦
Expandable either left or right, cable connected.
Restrictions
The system must consist of one (1) primary power/distribution bay or primary power only bay and may consist of up to seven
(7) additional bays. These additional bays may be a combination of secondary power/distribution bays, secondary power only
bays, and/or distribution only bays (maximum of 4 distribution only bays per system).
Requires external main battery termination bars.
Ordering Notes
1)
(208 VAC Input).
2)
Order rectifiers as required per
(480 VAC Input) or
(208 VAC Input).
3)
List 5: Order additional MCA customer alarm relay circuit card(s) as required per
, and optional MCA I/O circuit
cards per
. Order optional LMS Monitor and LMS options as required per
, and SAG586505000. Order a
Battery Charge Temperature Compensation Probe as required per
Battery Charge Temperature Compensation Probe for
ACCESSORY DESCRIPTIONS
section.
4)
List 105: Order temperature probes as required per
in the
ACCESSORY DESCRIPTIONS
section.
5)
Order bay grounding lugs as required per
Power Only Bay Frame Grounding Wire Sizes and Lugs
ACCESSORY
DESCRIPTIONS
section.
6)
Order DC output cable lugs as required per
Power Only Bay DC Output Cable Sizes and Lugs
ACCESSORY
DESCRIPTIONS
section.
7)
Order AC input lugs as required per
Power Only Bay AC Input, Ten (10) Rectifier Feed Wire Sizes, Branch Circuit
in the
ACCESSORY DESCRIPTIONS
section.
8)
Order external top-mount battery input busbar assembly, busbar shield kit, external top-mount ground (load return)
busbar assembly, and/or load return lug extension busbar assembly as required per the appropriate sections located
under
9)
If the system is to be connected to an existing system with an MCA, refer to List 64, 65, 66, and 67.
List 11 and 111: Secondary Power/Distribution Bay (Common Equipment)
Features
♦
Provides common equipment for one (1) “power and distribution” bay rated for up to 2400 amperes.
♦
Mounted in a 93.5"H x 24"W x 30"D box framework.
♦
Provides ten (10) rectifier mounting positions.
♦
Provides an AC input termination panel that accepts ten (10) AC input branch circuits, one (1) per rectifier mounting
position.
♦
Provides forty-eight (48) distribution device mounting positions.
♦
Provides two (2) buses of distribution. When used with the MCA, each bus contains a monitoring circuit card; which can
be set for no group designation, Group A designation, or Group B designation.
♦
Configured for a 4000 A internal bus or external main battery termination bars.
♦
Includes a router or CAN interface assembly for bay communication to the controller/monitor in the primary power bay.
♦
List 11: Provides mounting for optional LMS Expansion CPU circuit card. Provides a seven-slot card cage for mounting
MCA customer alarm relay circuit cards, MCA I/O circuit cards, and/or optional LMS I/O circuit cards.
♦
List 111: Includes the SM-DUE. Refer to “