Appendix C: Technical Specifications
Physical Data
Dimensions
23.6 in. X 45.7 in. X 78.7 in. (600 mm X 1162 mm X 2000 mm)
Weight =/- 5%
Dry 796 lbs. (361 kg), Wet 847 lbs. (384 kg)
Output Capacity
Power supply
208 V, 3 PH, 60 Hz
Full load current
15A at 208 V
Maximum Power
3.0 kW (at 100% fan speed)
Nominal Power
1.3 kW (at 50% fan speed)
Performance Data—at 113°F (45°C) Water Delivery and 75°F (24°C) Air Inlet
Nominal cooling capacity
32.1 kW (at 50% fan speed)
Maximum cooling capacity
52.2 kW (at 100% fan speed)
Nominal fluid flow
12.2 USGPM (46.2 l/min.)
Maximum fluid flow
19.9 USGPM (46.2 l/min)
Nominal air flow
1663 CFM at 50% fan speed (2825 m3/h)
Maximum air flow
3325 CFM (5650 m3/h)
Performance Data—at 122°F (50°C) Water Delivery and 75°F (24°C) Air Inlet*
Nominal cooling capacity
32.1 kW (at 50% fan speed)
Maximum cooling capacity
63.0 kW (at 100% fan speed)
Nominal fluid flow
14.4 USGPM (54.5 l/min.)
Maximum fluid flow
24.0 USGPM (90.8 l/min)
Nominal air flow
1663 CFM at 50% fan speed (2825 m3/h)
Maximum air flow
3325 CFM (5650 m3/h)
*Performance data was calculated with a 18°F (10°C) water side delta T.
Additional Features
Maximum equivalent distance from heat load
25 ft. (7.6m)
Filtration
50 micron filter
Liebert XDU water volume
6.2 gallons
57
Summary of Contents for Liebert XDU 060
Page 1: ...Liebert XDU Liquid to Air Heat Exchanger for Chip Cooling Installer User Guide 600 mm Wide ...
Page 10: ...Vertiv XDU Liquid to Air Heat Exchanger for Chip Cooling 6 This page intentionally left blank ...
Page 38: ...Vertiv XDU Liquid to Air Heat Exchanger for Chip Cooling 34 ...
Page 74: ...Vertiv XDU Liquid to Air Heat Exchanger for Chip Cooling ...