LIEBERT® PSA itON-SOHO 

650/850/1000VA, 230V

User Manual

1

  Liebert® PSA itON-SOHO User Manual (R1/071621)

SETUP

1.  Inspect the Package

Inspect the package and the UPS upon receipt. Notify the 

carrier and dealer of visible damage.

2.  Decide where to place the UPS

The UPS must be placed indoors, protected from water, direct 

sunlight and excessive heat. Provide at least 7.8” (20 cm) of 

clearance on all sides of the unit for proper ventilation.

3.  Charge the UPS battery before use

The UPS battery is fully charged before shipping. However, 

some charge may be lost during shipping and the battery 

should be recharged prior to use.

•  Plug in the AC input cord of the UPS to the wall outlet.  

It is recommended to charge the battery at least 4 hours 

before initial use. The unit charges its battery while 

connected to the utility.

4.  Start the UPS

After the battery is fully charged:

•  Turn on the UPS by pressing the On/Off button. (see figure 

below) LED1 should be illuminated (green), indicating the 

UPS is operating in Normal Mode.

5.  Connect the loads

The UPS has dedicated backup outlets that provide power 

when the UPS operates on battery. 

(see UPS Controls and 

Connections on next page)

•  Plug the loads into the battery backup outlets on the side 

panel of the UPS

CAUTION: 

Never connect a laser printer or scanner to the UPS 

unit. This may damage the unit.

IMPORTANT SAFETY INSTRUCTIONS 

Save these instructions:

This manual contains important instructions that should be followed 

during installation and maintenance of the UPS.

•  Intended for installation in a controlled environment.
•  Maximum ambient temperature 104°F (40°C)

CAUTION! 

To prevent the risk of fire or electric shock, install in a 

temperature and humidity controlled indoor area free of conductive 
contaminants. (See the specifications for the acceptable temperature 
and humidity range.)

CAUTION! 

To reduce the risk of overheating the UPS, do not cover  

the UPS’s cooling vents and avoid exposing the unit to direct sunlight or 
installing the unit near heat emitting appliances such as space heaters or 
furnaces.

CAUTION! 

Do not attach non-computer-related items, such as medical 

equipment, life-support equipment, microwave ovens, or vacuum 
cleaners to UPS.

CAUTION! 

Do not plug the UPS input into its own output.

CAUTION! 

Do not allow liquids or any foreign object to enter the UPS.  

Do not place beverages or any other liquid-containing vessels on or near 
the unit.

CAUTION! 

In the event of an emergency, press the OFF button and 

disconnect the power cord from the AC power supply to properly disable 
the UPS.

CAUTION! 

Do not attach a power strip or surge suppressor to the UPS.

CAUTION! 

If the UPS is with metal chassis, for safety purpose, grounding 

is a must during UPS installation in order to reduce leakage current  
below 3.5mA.

CAUTION! 

When replacing the batteries, use the same number and  

type of batteries.

CAUTION! 

Internal battery voltage is 12VDC. Sealed, lead-acid,  

6-cell battery.

CAUTION! 

Electric shock hazard. When UPS is disconnected from the 

mains source, hazardous voltage may still be available through the 
batteries. Disconnect all battery connectors from battery terminals prior 
to doing any maintenance or service works.

CAUTION! 

Servicing of batteries should be performed or supervised by 

personnel knowledgeable of batteries and the required precautions. 
Keep unauthorized personnel away from batteries.

CAUTION! 

Do not dispose of batteries in a fire. The battery may explode. 

Do not open or mutilate the battery or batteries. Released electrolyte is 
harmful to the skin and eyes.

CAUTION! 

Unplug the UPS prior to cleaning and do not use liquid or 

spray detergent.

CAUTION! 

A battery can present a risk of electric shock and high short 

circuit current. The following precaution should be observed before 
replacing batteries:

1.  Remove watches, rings, or other metal objects.

2.  Use tools with insulated handles.
3.  Wear rubber gloves and boots.

4.  Do not lay tools or metal parts on top of batteries.

5.  Disconnect charging source prior to connecting or  

disconnecting batteries terminal.

UPS

Quick-start 

Guide

1 x Power Cable

As Output Cable:

As Input Cable:

TO WALL 
SOCKET

TO DESKTOP/PC

Power Button

20CM

CLEARANCE