Figure 17.6
Removing the Fan Shroud and Defective Fan
Carefully slide the defective fan with inner mounting plate attached out far enough to disconnect the fan connectors.
Set the fan inner mounting plate with fans attached on a suitable work surface.
Separate the defective fan from the fan inner mounting plate by removing the (4) sets of screws and star washers.
Discard the defective fan. Refer to Figure 17.5.
Attach the replacement fan to the fan inner mounting plate with the (4) sets of screws and star washers previously
removed.
Carefully slide the fan inner mounting plate with fans attached into the mounting position far enough to reconnect the
fan connectors.
Slide the fan inner mounting plate with fans attached all the way in and secure with the (4) sets of flat washers, lock
washers, and nuts previously removed.
10.
Using the hardware previously removed, replace the heat exchanger’s upper shroud (internal fan) or lower shroud (external
fan).
11.
Enable the HX fans by either...